MCCB 3P 250A 70kA Standard Electronic 250A Frame NM8N Chint
Chint NM8N 250A 3P MCCB features 70kA breaking capacity, standard electronic trip unit and a 250A frame. Ideal for switchboard mains and sub-mains protection.
Sign in
Please login to continue to your account.
Alternatively Known As: CHINT NM8N 250A MCCB, 250AF moulded case circuit breaker, 3-phase electronic MCCB, 70kA MCCB
- Product Type: Moulded case circuit breaker
- Number of Poles: 3P
- Frame Size: 250A
- Rated Current: 250A
- Trip Unit: Standard electronic type, EM
- Breaking Capacity: 70kA at 380–440V AC
- Service Breaking Capacity: 100% of Icu at rated conditions
- Rated Operational Voltage: 380/400/415V AC, with additional ratings up to 690V AC
- Rated Insulation Voltage: 1000V
- Rated Impulse Withstand Voltage: 8kV
- Rated Frequency: 50/60Hz
- Utilisation Category: A
- Installation: Fixed surface mounting
- Terminal Connection: Screw terminals
- Ingress Protection: IP40
- Operating Temperature: -40°C to +70°C
- Mechanical Life: Up to 25,000 operating cycles
- Electrical Life: Up to 10,000 operating cycles at 415V AC
- Dimensions (H x L x W): 157mm x 88.7mm x 105mm
- Weight: 1.85 kg
- 70kA short-circuit breaking capacity for high-fault-level distribution systems
- 250A frame with 250A rated current
- Three-pole configuration for three-phase power distribution
- Standard electronic trip unit for adjustable overload and short-circuit protection
- Suitable for switchboard mains and sub-mains protection
- Suitable for isolation when installed in accordance with the manufacturer's instructions
- Compatible with optional auxiliary, alarm, shunt-trip, undervoltage-release and operating-mechanism accessories
- Certified product family tested to IEC/EN 60947-2 requirements
- Installation, testing and commissioning must be performed by a licensed electrician in accordance with AS/NZS 3000, applicable switchboard requirements and the manufacturer's instructions. Verify fault level, discrimination, cable capacity, tightening torque and Australian regulatory registration before energising.
- Switchboard mains protection
- Switchboard sub-mains protection
- Commercial and industrial power distribution
- Three-phase feeder protection
- Electrical equipment and distribution-board protection
- Data centre and infrastructure power distribution
- AS/NZS IEC 60947.2 applicable to low-voltage circuit-breakers
- AS/NZS 3000 Wiring Rules apply to selection and installation within Australian electrical installations
- Confirm RCM and local regulatory registration requirements for the supplied variant before installation
- Electronic trip control can support more precise protection settings and reduce unnecessary equipment replacement
- Long mechanical and electrical service life can reduce replacement frequency and associated waste
- Metal and engineering-plastic components can be separated for recycling at end of service life
- RoHS declaration is available for the NM8N product family, supporting restriction of hazardous substances
CHINT's general warranty policy specifies 27 months from the date of manufacture for other low-voltage apparatus sold through authorised channels, subject to the applicable sales contract and warranty conditions.
Available through authorised CHINT distributors in Australia.