MCCB 3P 25A 36kA Magnetic Only 125A Frame NM8N Chint
Chint NM8N 25A 3P MCCB features 36kA breaking capacity, magnetic-only trip unit for motor protection and a 125A frame. Ideal for switchboard mains protection.
Sign in
Please login to continue to your account.
Alternatively Known As: Moulded Case Circuit Breaker, Magnetic MCCB, Motor Protection MCCB, NM8N-125C M 25A 3P
- Product Type: Moulded case circuit breaker
- Number of Poles: 3P
- Rated Current: 25A
- Frame Current: 125A
- Trip Unit: Magnetic-only electromagnetic release
- Breaking Capacity: 36kA at 380–440V AC
- Rated Operational Voltage: Up to 690V AC, depending on system conditions
- Rated Insulation Voltage: 1000V
- Rated Impulse Withstand Voltage: 8kV
- Rated Frequency: 50/60Hz
- Magnetic Trip Setting: Approximately 12 times rated current
- Connection Type: Fixed or plug-in mounting
- Isolation Function: Suitable for isolation
- Terminal Torque: 6Nm for M6 terminals
- Dimensions (H x L x W): 140mm x 78.5mm x 90mm
- Weight: 1.05 kg
- Three-pole protection for low-voltage AC systems
- Magnetic-only trip unit provides short-circuit protection without thermal overload protection
- 125A frame accommodates a 25A rated current
- 36kA ultimate and service short-circuit breaking capacity at 380–440V AC
- Suitable for motor circuit short-circuit protection where overload protection is provided separately
- Can be installed vertically or horizontally with top or bottom line entry
- Optional auxiliary, shunt-release, undervoltage-release and motor-operated accessories are available for the NM8N series
- Installation, selection of protective settings and connection to a switchboard or motor circuit should be performed by a licensed electrician in accordance with AS/NZS 3000 and the manufacturer's installation instructions. Magnetic-only protection does not replace separate overload protection where required.
- Motor circuit short-circuit protection with separate overload protection
- Industrial switchboards
- Commercial electrical distribution boards
- Low-voltage AC control and power circuits
- Machinery and motor control panels
- Main or sub-main protection where the system design permits magnetic-only tripping
- AS/NZS IEC 60947.2:2015 – applicable product standard for low-voltage circuit-breakers and MCCBs
- AS/NZS 3000 – installation and wiring requirements for electrical installations
- Metallic conductive components and the thermoplastic housing can be separated for responsible end-of-life recycling
- Long mechanical service life can reduce replacement frequency and associated material waste
- Magnetic-only operation avoids continuous electronic sensing power consumption
CHINT warranty policy provides 27 months from the date of manufacture for other low-voltage apparatus when purchased through authorised sales channels, subject to applicable contract terms.