MCCB 3P 50A 36kA Magnetic Only 125A Frame NM8N Chint
Chint NM8N 50A 3P MCCB features 36kA breaking capacity, magnetic-only trip unit for motor protection and a 125A frame. Ideal for switchboard mains protection.
Sign in
Please login to continue to your account.
Alternatively Known As: CHINT NM8N 125AF MCCB, 50A Motor Protection MCCB, 3P Magnetic Circuit Breaker, Moulded Case Circuit Breaker
- Model: NM8N-125C M 50 3P
- Product Type: Moulded case circuit breaker
- Number of Poles: 3P
- Rated Current: 50A
- Frame Rating: 125A frame
- Breaking Capacity: 36kA Icu at 380/400/415V AC
- Trip Unit: Magnetic-only type for motor protection
- Rated Operational Voltage: 380/400/415V AC
- Frequency: 50/60Hz
- Rated Insulation Voltage: 1000V
- Rated Impulse Withstand Voltage: 8kV
- Utilisation Category: A
- Connection: Fixed, front connection
- Dimensions (H x L x W): 140mm x 78.5mm x 90mm
- Weight: 1.19 kg
- Three-pole protection for three-phase circuits
- Magnetic-only trip unit designed for motor circuit short-circuit protection
- 125A frame with a 50A rated current
- 36kA ultimate short-circuit breaking capacity at 380/400/415V AC
- Suitable for switchboard and industrial distribution applications
- Can be coordinated with a separate overload relay for complete motor protection
- Compatible with optional MCCB accessories including auxiliary and alarm contacts
- Installation, selection and commissioning should be performed by a licensed electrician in accordance with the manufacturer's instructions, applicable wiring rules and switchboard requirements. Magnetic-only motor protection must be coordinated with suitable overload protection where required.
- Motor feeder short-circuit protection
- Three-phase industrial equipment
- Switchboard outgoing circuits
- Commercial and industrial power distribution
- Mains and sub-main protection where magnetic-only protection is appropriate
- AS/NZS IEC 60947.2 for low-voltage circuit-breakers
- Durable moulded-case construction can support a long service life and reduce replacement waste
- Copper, aluminium and steel components are generally recoverable through appropriate electrical equipment recycling streams
- Reusable resettable protection avoids routine replacement after a non-destructive trip
CHINT's general policy provides 27 months from the date of manufacture against defects in materials and workmanship for other low-voltage apparatus sold through authorised channels. Australian sale and contract conditions may vary.