MCCB 3P 630A 36kA Thermal Magnetic 800A Frame NM8N Chint
Chint NM8N 630A 3P MCCB features 36kA breaking capacity, thermal-magnetic trip unit and a 800A frame. Ideal for switchboard mains and sub-mains protection.
Sign in
Please login to continue to your account.
Alternatively Known As: CHINT NM8N-800C TM 630 3P MCCB, moulded case circuit breaker, 630A 3-pole circuit breaker
- Product Type: Moulded case circuit breaker
- Frame Current: 800A
- Rated Current: 630A
- Number of Poles: 3P
- Trip Unit: Thermal-magnetic
- Breaking Capacity: 36kA at AC 380/400/415V
- Rated Operational Voltage: AC 380/400/415V, 440V, 500V and 660/690V
- Rated Frequency: 50/60Hz
- Utilisation Category: A
- Isolation Function: Suitable for isolation
- Product Standard: IEC/EN 60947-2
- Insulation Voltage: 1000V
- Rated Impulse Withstand Voltage: 12kV
- Dimensions (H x L x W): 300mm x 133mm x 195mm
- Weight: 13 kg
- 800A frame with a 630A thermal-magnetic trip rating
- 36kA ultimate and service short-circuit breaking capacity at AC 380/400/415V
- Three-pole configuration for three-phase power distribution
- Thermal protection for overload conditions and magnetic protection for short circuits
- Suitable for switchboard mains, sub-mains and high-current distribution circuits
- Suitable for isolation when installed in accordance with the manufacturer’s instructions
- Compact fixed-type MCCB construction for panelboard and switchboard installation
- Installation, selection and testing must be performed by a licensed electrician in accordance with AS/NZS 3000, the manufacturer’s instructions and applicable switchboard requirements. Confirm fault levels, discrimination, cable ratings, clearances and local RCM requirements before installation.
- Main incoming protection in low-voltage switchboards
- Sub-main and feeder protection
- Commercial and industrial power distribution
- Protection of high-current three-phase circuits
- Switchboard upgrade and replacement applications
- AS/NZS IEC 60947.2:2015 is the applicable Australian and New Zealand standard for low-voltage circuit-breakers; verify product certification and RCM suitability for the intended Australian installation.
- Manufacturer product documentation specifies IEC/EN 60947-2 design compliance.
- RoHS documentation is available for the NM8N product family, supporting restricted-substance compliance.
- Long service life can reduce replacement frequency and associated material waste.
- Copper, aluminium and steel components can be recovered through appropriate electrical equipment recycling streams.
- Overload and short-circuit protection helps prevent damage to downstream electrical equipment and reduce premature replacement.
CHINT warranty policy provides 27 months from the date of manufacture for other low-voltage apparatus sold through authorised sales channels, subject to the applicable contract and warranty conditions.
Available through authorised CHINT distributors in Australia.
