MCCB 3P 630A 50kA Thermal Magnetic 800A Frame NM8N Chint
Chint NM8N 630A 3P MCCB features 50kA breaking capacity, thermal-magnetic trip unit and a 800A frame. Ideal for switchboard mains and sub-mains protection.
Sign in
Please login to continue to your account.
Alternatively Known As: Moulded Case Circuit Breaker, MCCB, Thermal-Magnetic Circuit Breaker, 630A 3P Circuit Breaker
- Rated Current: 630A
- Frame Size: 800A
- Number of Poles: 3P
- Breaking Capacity: 50kA at 380/415V AC
- Trip Unit: Adjustable thermal-magnetic
- Thermal Overload Adjustment: 0.7–1.0 x In
- Instantaneous Short-Circuit Adjustment: 5–10 x In, ±20%
- Rated Operational Voltage: Up to 690V AC
- Rated Insulation Voltage: 1,000V
- Rated Impulse Withstand Voltage: 12kV
- Mechanical Durability: Up to 15,000 operations
- Electrical Durability: Up to 2,000 operations at 400V AC
- Product Standard: IEC/EN 60947-2
- Dimensions (H x L x W): 300mm x 113mm x 195mm
- Weight: 10.5 kg
- 50kA short-circuit breaking capacity at 380/415V AC
- Three-pole configuration for three-phase distribution systems
- Adjustable thermal protection for overload conditions
- Adjustable magnetic protection for short-circuit conditions
- 800A frame with 630A rated current
- Suitable for fixed front connection applications
- Can be used for switchboard mains and sub-mains protection
- Designed for low-voltage power distribution systems
- Installation, testing and commissioning must be performed by a licensed electrician in accordance with AS/NZS 3000, the manufacturer's instructions and applicable switchboard requirements. Verify fault levels, discrimination, cable ratings and terminal compatibility before installation.
- Switchboard mains protection
- Sub-main and feeder protection
- Commercial and industrial power distribution
- Three-phase low-voltage distribution boards
- Protection of cables and downstream electrical equipment from overload and short circuit
- Applicable product standard: AS/NZS IEC 60947.2 for low-voltage circuit-breakers
- Installation should comply with AS/NZS 3000 Wiring Rules
- Helps prevent premature damage to cables and downstream equipment, reducing replacement waste
- Long mechanical and electrical service life can reduce product replacement frequency
- Supports maintainable and energy-efficient low-voltage distribution system design
CHINT warranty policy provides 27 months from the date of manufacture for other low-voltage apparatus purchased through authorised sales channels, subject to contract terms and warranty conditions.
Available through authorised CHINT distributors in Australia.