MCCB 3P 63A 36kA Magnetic Only 125A Frame NM8N Chint
Chint NM8N 63A 3P MCCB features 36kA breaking capacity, magnetic-only trip unit for motor protection and a 125A frame. Ideal for switchboard mains protection.
Sign in
Please login to continue to your account.
Alternatively Known As: CHINT NM8N-125C M 63A 3P MCCB, magnetic motor protection circuit breaker, moulded case circuit breaker
- Frame Size: 125A
- Rated Current: 63A
- Number of Poles: 3P
- Release Type: Magnetic-only, M type
- Breaking Capacity: 36kA at 380/400/415/440V AC
- Rated Operational Voltage: Up to 690V AC
- Rated Insulation Voltage: 1000V
- Rated Impulse Withstand Voltage: 8kV
- Magnetic Trip Setting: 12 x In, approximately 756A for a 63A breaker
- Magnetic Trip Accuracy: ±20%
- Frequency: 50/60Hz
- Mounting: Fixed type
- Selectivity Category: A
- Applicable Product Standards: IEC 60947-1 and IEC 60947-2
- Dimensions (H x L x W): 140mm x 78.5mm x 90mm
- Weight: 1.19 kg
- Three-pole moulded case circuit breaker for low-voltage AC systems
- 125A frame with a 63A rated current
- Magnetic-only release designed for motor short-circuit protection
- 36kA short-circuit breaking capacity at common three-phase voltages
- Suitable for fixed switchboard installation
- Can be used with a contactor and separate thermal overload relay in motor starter applications
- Supports isolation and manual circuit interruption
- Installation and commissioning should be performed by a licensed electrician in accordance with AS/NZS 3000, the manufacturer's instructions and applicable switchboard requirements. Magnetic-only protection does not provide overload protection, so motor circuits require suitable external overload protection where applicable.
- Motor feeder short-circuit protection used with a contactor and thermal overload relay
- Industrial and commercial switchboards
- Three-phase distribution and feeder circuits
- Mains or sub-main protection where the overall protection design includes suitable overload protection
- Low-voltage AC electrical equipment requiring a 36kA MCCB
- AS/NZS IEC 60947.2:2015 is the applicable Australian/New Zealand standard for low-voltage circuit-breakers
- Installation wiring and switchboard integration should comply with AS/NZS 3000 and applicable switchboard requirements
- Durable moulded-case construction can support extended service life and reduce replacement waste
- Fault isolation can help limit damage to connected electrical equipment and associated material waste
- Metal electrical components are generally recoverable through appropriate electrical equipment recycling streams
CHINT's general warranty policy states 27 months from the date of manufacture for other low-voltage apparatus sold through authorised sales channels; local Australian terms and contract conditions may apply.
Available through authorised CHINT distributors in Australia.