MCCB 3P 800A 150kA Magnetic Only 800A Frame NM8N Chint
Chint NM8N 800A 3P MCCB features 150kA breaking capacity, magnetic-only trip unit for motor protection and a 800A frame. Ideal for switchboard mains protection.
Sign in
Please login to continue to your account.
Alternatively Known As: CHINT NM8N 800A MCCB, 800A Motor Protection Circuit Breaker, 150kA Magnetic MCCB
- Series: NM8N-800R
- Rated Current: 800 A
- Number of Poles: 3P
- Trip Unit: Magnetic-only release for motor protection
- Ultimate Breaking Capacity: 150 kA
- Frame Size: 800 A
- Rated Operational Voltage: Up to 690 V AC
- Rated Insulation Voltage: 1,000 V AC
- Rated Impulse Withstand Voltage: 8 kV
- Release Adjustment: Approximately 9–14 times In
- Connection Type: Fixed front connection
- Utilisation Category: Category A
- Ingress Protection: IP00, or IP40 when fitted with terminal covers
- Dimensions (H x L x W): 300mm x 195mm x 133mm
- Weight: 18 kg
- 150kA high breaking capacity for high-fault-level installations
- Magnetic-only trip unit suited to motor protection schemes
- 800A frame with an 800A rated current
- Three-pole configuration for three-phase systems
- Suitable for integration with contactors and thermal overload relays
- Compatible with optional accessories including auxiliary contacts, shunt trip, undervoltage release and motor operator
- Designed for switchboard and industrial power distribution applications
- Installation, commissioning and protection coordination should be completed by a licensed electrician or suitably qualified electrical professional. The magnetic-only release does not provide thermal overload protection, so a correctly selected thermal overload relay or equivalent motor protection device is required where applicable. Install in accordance with the manufacturer's instructions, applicable wiring rules and local certification requirements.
- Switchboard mains protection
- Industrial three-phase distribution systems
- Motor protection arrangements using a contactor and separate thermal overload relay
- High prospective short-circuit current installations
- Commercial and industrial power distribution assemblies
- Applicable Australian standard: AS/NZS IEC 60947.2 for low-voltage circuit-breakers; verify product certification, RCM requirements and suitability for the intended Australian installation before use
- Long service life and replaceable accessories can reduce equipment replacement waste
- Metal components can generally be recovered and recycled at end of service life
- Low-voltage switchboard protection supports safer, more reliable operation of electrical systems
CHINT warranty policy generally covers other low-voltage apparatus against defects in materials and workmanship for 27 months from the date of manufacture when purchased through authorised sales channels; contractual or local distributor conditions may apply.
Available through authorised CHINT distributors in Australia.