MCCB 3P 800A 36kA Magnetic Only 800A Frame NM8N Chint
Chint NM8N 800A 3P MCCB features 36kA breaking capacity, magnetic-only trip unit for motor protection and a 800A frame. Ideal for switchboard mains protection.
Sign in
Please login to continue to your account.
Alternatively Known As: NM8N-800C M 800 3P MCCB, Magnetic MCCB, Moulded Case Circuit Breaker, Motor Protection MCCB
- Frame Size: 800A
- Rated Current: 800A
- Number of Poles: 3P
- Release Type: Magnetic-only
- Breaking Capacity: 36kA at AC 380/400/415V
- Magnetic Trip Setting: 9–14 times rated current
- Rated Insulation Voltage: 1,000V
- Rated Operational Voltage: AC 380/400/415V; variant-dependent operation up to 690V
- Rated Frequency: 50/60Hz
- Impulse Withstand Voltage: 12kV
- Service Suitability: Suitable for isolation
- Mechanical Durability: Up to 15,000 operations
- Electrical Durability: Up to 1,500 operations
- Ingress Protection: IP20
- Power Loss: Approximately 51.2W per pole at 800A
- Dimensions (H x L x W): 300mm x 193mm x 195mm
- Weight: 10.48 kg
- 800A moulded case circuit breaker for high-current low-voltage installations
- Three-pole configuration for three-phase systems
- Magnetic-only instantaneous short-circuit protection
- Adjustable magnetic trip range for motor circuit protection
- 36kA ultimate and service breaking capacity at AC 380/400/415V
- Suitable for switchboard mains and feeder protection
- Suitable for isolation
- Designed for use with contactors and thermal overload relays in motor protection arrangements
- Installation, commissioning and adjustment must be performed by a licensed electrician or suitably qualified electrical professional. Select and install the breaker in accordance with the manufacturer's instructions, AS/NZS 3000, AS/NZS 60947.2 and the switchboard assembly requirements. A magnetic-only release does not provide overload protection and must be coordinated with suitable motor overload protection where required.
- Main switchboard protection
- Three-phase feeder protection
- High-current distribution boards
- Motor circuit short-circuit protection when coordinated with a contactor and thermal overload relay
- Industrial and commercial power distribution systems
- AS/NZS 60947.2 for low-voltage circuit-breakers, subject to verification of the specific Australian-approved product variant
- AS/NZS 3000 for selection and installation within electrical installations
- AS/NZS 61439 may apply to the completed low-voltage switchboard assembly
- Long mechanical and electrical service life can reduce replacement frequency and product waste
- Reusable moulded-case construction supports maintenance and replacement of accessories rather than complete system replacement
- Magnetic-only protection avoids standby electronic control circuitry and associated electronic component waste
- Can support reliable operation of high-efficiency motor and power distribution systems when correctly coordinated
CHINT warranty policy specifies 27 months from the date of manufacture for other low-voltage apparatus sold through authorised channels. Contractual terms and local distributor conditions may vary.
Available through authorised CHINT distributors in Australia.