MCCB 4P 100A 150kA Standard Electronic 250A Frame NM8N Chint
Chint NM8N 100A 4P MCCB features 150kA breaking capacity, standard electronic trip unit with protected neutral and a 250A frame. For switchboard mains protection.
Sign in
Please login to continue to your account.
Alternatively Known As: CHINT NM8N-250R EN 4P 100A MCCB, 4-Pole Moulded Case Circuit Breaker, Electronic MCCB
- Rated Current: 100A
- Number of Poles: 4P
- Frame Size: 250A
- Trip Unit: Standard electronic release
- Neutral Protection: Protected neutral pole
- Rated Breaking Capacity: 150kA at 415V AC
- Rated Operational Voltage: Up to 690V AC, 50/60Hz
- Rated Insulation Voltage: 1000V
- Rated Impulse Withstand Voltage: 8kV
- Protection Functions: Overload, short-circuit and earth-fault protection
- Installation Configuration: Fixed mounting with top or bottom line entry
- Product Standard: IEC/EN 60947-2
- Dimensions (H x L x W): 157mm x 140mm x 88.7mm
- Weight: 2.65 kg
- Four-pole protection for three-phase systems with neutral
- 100A electronic trip rating within a 250A frame
- 150kA high short-circuit breaking capacity at 415V AC
- Protected neutral pole for enhanced four-wire system protection
- Electronic protection against overload and short-circuit conditions
- Suitable for switchboard mains and secondary distribution applications
- Can be installed vertically or horizontally
- Compatible with optional CHINT accessories and motorised operating mechanisms
- Installation, testing and commissioning must be performed by a licensed electrician in accordance with the manufacturer's instructions, AS/NZS 3000 and applicable switchboard requirements. Verify system fault levels, discrimination, conductor sizing and local certification before installation.
- Switchboard mains protection
- Commercial and industrial low-voltage distribution boards
- Three-phase four-wire power distribution systems
- High prospective fault-current installations
- Protection of feeders, busbars and major electrical equipment
- Applicable Australian/New Zealand product standard: AS/NZS IEC 60947.2:2015 for low-voltage circuit-breakers; the manufacturer documentation specifies IEC/EN 60947-2. Verify RCM and local approval requirements for the specific imported variant.
- Installation within an assembly should comply with the applicable AS/NZS 61439 requirements and AS/NZS 3000.
- Long service life and high fault protection can reduce replacement of damaged switchboard equipment
- Metal components and thermoplastics can be separated for recycling at end of service life where suitable recycling facilities are available
- Electronic protection supports selective fault clearing and can help limit the extent of equipment damage
CHINT's general warranty policy states 27 months from the date of manufacture for other low-voltage apparatus sold through authorised channels. Contract terms, exclusions and local distributor conditions may apply.
Available through authorised CHINT distributors in Australia.