MCCB 4P 160A 150kA Standard Electronic 250A Frame NM8N Chint
Chint NM8N 160A 4P MCCB features 150kA breaking capacity, standard electronic trip unit with protected neutral and a 250A frame. For switchboard mains protection.
Sign in
Please login to continue to your account.
Alternatively Known As: NM8N-250R EM 4P 160A MCCB, 250A Frame Moulded Case Circuit Breaker, Four-Pole Electronic MCCB
- Product Type: Moulded case circuit breaker
- Series: NM8N
- Poles: 4P
- Rated Current: 160A
- Frame Size: 250A
- Breaking Capacity: 150kA
- Trip Unit: Standard electronic EM release
- Neutral Protection: Protected neutral with adjustable settings
- Rated Insulation Voltage Ui: 1000V
- Rated Operational Voltage Ue: Up to 690V AC
- Rated Frequency: 50/60Hz
- Protection Functions: Long-time overload, short-time short-circuit, instantaneous short-circuit and earth-fault protection
- Installation: Fixed mounting
- Mechanical Life: Up to 25,000 operating cycles
- Dimensions (H x L x W): 157mm x 88.7mm x 140mm
- Weight: 2.65 kg
- Four-pole protection for three-phase systems with neutral
- 150kA ultimate short-circuit breaking capacity
- 250A frame with 160A rated current
- Standard electronic trip unit with adjustable protection parameters
- Provides overload, short-circuit and earth-fault protection
- Protected neutral pole with adjustable neutral protection current
- Suitable for switchboard mains and low-voltage power distribution applications
- Can be installed with top or bottom line entry
- Designed for low-voltage AC distribution systems
- Installation, testing and commissioning should be performed by a licensed electrician in accordance with the manufacturer's instructions, AS/NZS 3000 and applicable switchboard requirements. Confirm prospective fault current, discrimination, cable ratings and trip settings before energising.
- Main incoming protection in commercial switchboards
- Industrial power distribution boards
- Three-phase building services distribution
- Data centre and infrastructure switchboards
- High-fault-level low-voltage distribution systems
- Protection of feeders, bus sections and major electrical equipment
- Applicable product standard: AS/NZS IEC 60947.2:2015 for low-voltage circuit-breakers
- Installation is subject to AS/NZS 3000 requirements
- Metal components can be recovered and recycled at end of service life
- Adjustable electronic protection can improve coordination and reduce unnecessary equipment replacement
- Long mechanical service life helps reduce replacement frequency and material waste
CHINT warranty policy generally provides 27 months from the date of manufacture for other low-voltage apparatus purchased through authorised sales channels, subject to the applicable sales contract and warranty conditions.
Available through authorised CHINT distributors in Australia.