MCCB 4P 160A 150kA Thermal Magnetic 250A Frame NM8N Chint
Chint NM8N 160A 4P MCCB features 150kA breaking capacity, thermal-magnetic trip unit with protected neutral and a 250A frame. For switchboard mains protection.
Sign in
Please login to continue to your account.
Alternatively Known As: CHINT NM8N-250R 160A MCCB, 4P Moulded Case Circuit Breaker, Thermal-Magnetic Circuit Breaker
- Rated Current: 160A
- Frame Size: 250A
- Number of Poles: 4P
- Trip Unit: Thermal-magnetic
- Ultimate Short-Circuit Breaking Capacity: 150kA at 380/400/415V AC
- Service Short-Circuit Breaking Capacity: 150kA at 380/400/415V AC
- Rated Operational Voltage: 380/400/415V AC, with operation available up to 690V AC depending on breaking-capacity rating
- Rated Insulation Voltage: 1000V AC
- Rated Impulse Withstand Voltage: 8kV
- Rated Frequency: 50/60Hz
- Thermal Trip Adjustment: 0.7–1.0 x In for 4-pole configurations
- Magnetic Trip Adjustment: 7–12 x In for 125–160A thermal-magnetic models
- Neutral Configuration: Protected neutral
- Utilisation Category: A
- Isolation: Suitable for isolation
- Mechanical Life: Up to 25,000 operating cycles
- Electrical Life: Up to 10,000 cycles at 415V AC and rated current
- Dimensions (H x L x W): 157mm x 140mm x 88.7mm
- Weight: 2.5 kg
- High 150kA short-circuit breaking capacity at 415V AC
- Four-pole construction for three-phase systems with neutral protection
- Adjustable thermal and magnetic trip settings
- 250A frame with a 160A rated current
- Suitable for switchboard incomer and mains protection applications
- Suitable for vertical or horizontal installation
- Top or bottom line entry capability
- Moulded-case construction with zero arcing distance
- Compatible with optional auxiliary, alarm, shunt-release and undervoltage accessories
- Installation, testing and commissioning should be performed by a licensed electrician in accordance with the manufacturer's instructions, AS/NZS 3000 and the requirements for low-voltage switchboards. Verify fault levels, protection settings, discrimination and enclosure assembly compliance before energising.
- Switchboard mains protection
- Three-phase commercial and industrial distribution boards
- Low-voltage power distribution systems
- Incomer protection for commercial buildings and industrial facilities
- Protection of feeders and high-fault-level distribution circuits
- AS/NZS IEC 60947.2 for low-voltage circuit-breakers
- Long mechanical and electrical service life can reduce replacement frequency and associated material waste
- Metal components in the breaker assembly can be recovered through appropriate electrical equipment recycling streams
- Adjustable protection settings support correct system coordination and can help minimise unnecessary equipment damage during faults
CHINT warranty policy for other low-voltage apparatus provides 27 months from the date of manufacture against defects in materials and workmanship when supplied through authorised sales channels; contract terms may vary.
Available through authorised CHINT distributors in Australia.