MCCB 4P 160A 36kA Thermal Magnetic 250A Frame NM8N Chint
Chint NM8N 160A 4P MCCB features 36kA breaking capacity, thermal-magnetic trip unit with protected neutral and a 250A frame. Ideal for switchboard mains protection.
Sign in
Please login to continue to your account.
Alternatively Known As: Moulded Case Circuit Breaker, 4-Pole MCCB, Thermal-Magnetic Circuit Breaker, NM8N-250C-160/4/22
- Rated Current: 160 A at 40°C
- Frame Size: 250 A
- Number of Poles: 4P
- Breaking Capacity: 36 kA at 380/400/415 V AC
- Trip Unit: Thermal-magnetic
- Thermal Trip Adjustment: 0.7–1.0 x In
- Magnetic Trip Adjustment: 7–12 x In for 125–160 A models
- Rated Insulation Voltage: 1,000 V AC
- Rated Impulse Withstand Voltage: 8 kV
- Rated Operational Voltage: 380/400/415 V AC, with versions available up to 690 V AC
- Frequency: 50/60 Hz
- Utilisation Category: A
- Isolation Function: Suitable for isolation
- Mechanical Life: 25,000 operating cycles
- Electrical Life: 10,000 operating cycles at 415 V AC and rated current
- Connection: Fixed front connection
- Product Standard: IEC/EN 60947-2
- Dimensions (H x L x W): 157mm x 88.7mm x 140mm
- Weight: 2.5 kg
- Four-pole configuration for three-phase systems with neutral switching
- 250 A frame fitted with a 160 A thermal-magnetic trip unit
- 36 kA ultimate and service short-circuit breaking capacity at 380/400/415 V AC
- Adjustable thermal and magnetic trip settings
- Suitable for switchboard mains and feeder protection
- Suitable for isolation
- Zero arcing distance design
- Accessory options include auxiliary contacts, shunt release and undervoltage release
- Installation, selection, adjustment and commissioning must be performed by a licensed electrician in accordance with the applicable wiring rules, fault-level requirements, manufacturer instructions and switchboard design standards.
- Switchboard mains protection
- Three-phase commercial and industrial distribution boards
- Feeder protection in low-voltage power distribution systems
- Motor and equipment supply protection where the selected trip characteristics are suitable
- Electrical distribution systems requiring four-pole isolation
- Product design is to IEC/EN 60947-2 for moulded-case circuit breakers; confirm the specific Australian-market unit's AS/NZS IEC 60947.2 conformity, RCM status and installation suitability before use in Australia
- Installation should comply with AS/NZS 3000 and applicable switchboard requirements
- Long mechanical and electrical service life can reduce replacement frequency and material waste
- Moulded-case circuit breakers contain recyclable metal conductors and hardware at end of service life
- Provides overcurrent protection that can help prevent damage to electrical equipment and associated material waste
CHINT's published warranty policy states 27 months from the date of manufacture for other low-voltage apparatus sold through authorised channels, subject to contract terms and warranty conditions.
Available through authorised CHINT distributors in Australia.