MCCB 4P 160A 50kA Standard Electronic 250A Frame NM8N Chint
Chint NM8N 160A 4P MCCB features 50kA breaking capacity, standard electronic trip unit with protected neutral and a 250A frame. For switchboard mains protection.
Sign in
Please login to continue to your account.
Alternatively Known As: NM8N-250S EM 4P 160A MCCB, 250A Frame MCCB, Electronic Moulded Case Circuit Breaker
- Rated Current: 160 A
- Frame Size: 250 A
- Number of Poles: 4P
- Breaking Capacity: 50 kA at AC 380/400/415 V
- Trip Unit: Standard electronic type with liquid-crystal display
- Neutral Protection: Protected neutral pole
- Rated Insulation Voltage Ui: 1000 V
- Rated Impulse Withstand Voltage Uimp: 8 kV
- Rated Operational Voltage: AC 380/400/415 V, up to 690 V
- Frequency: 50/60 Hz
- Utilisation Category: A
- Isolation Suitability: Suitable for isolation
- Mechanical Life: 25,000 operating cycles
- Electrical Life: 10,000 operating cycles at AC 415 V and rated current
- Manufacturing Standard: IEC/EN 60947-2
- Dimensions (H x L x W): 157mm x 88.7mm x 140mm
- Weight: 2.65 kg
- Four-pole moulded case circuit breaker for three-phase systems with neutral switching
- 250 A frame fitted with a 160 A standard electronic trip unit
- 50 kA short-circuit breaking capacity at common low-voltage supply voltages
- Electronic overload and short-circuit protection with adjustable protection settings
- Protected neutral function for improved system protection
- Suitable for main incomer and switchboard protection applications
- Suitable for isolation and low-voltage power distribution systems
- Installation, selection of protection settings and commissioning should be performed by a licensed electrician in accordance with AS/NZS 3000, the manufacturer's instructions and applicable switchboard requirements.
- Switchboard mains protection
- Commercial and industrial low-voltage distribution boards
- Main incoming protection for three-phase electrical systems
- Protection of cables, busbars and downstream distribution equipment
- Industrial buildings, commercial premises and data-centre power distribution
- AS/NZS IEC 60947.2:2015 for low-voltage circuit-breakers
- Installation should comply with AS/NZS 3000:2018 Wiring Rules
- CHINT NM8N product documentation includes a CE RoHS declaration for restricted hazardous substances
- Durable moulded-case construction can support extended service life and reduce replacement waste
- Copper, aluminium and steel components used in electrical switchgear are recyclable at end of service life
CHINT's general warranty policy specifies 27 months from the date of manufacture for other low-voltage apparatus purchased through authorised sales channels, subject to applicable contract terms.
Available through authorised CHINT distributors in Australia.