MCCB 4P 160A 50kA Thermal Magnetic 250A Frame NM8N Chint
Chint NM8N 160A 4P MCCB features 50kA breaking capacity, thermal-magnetic trip unit with protected neutral and a 250A frame. Ideal for switchboard mains protection.
Sign in
Please login to continue to your account.
Alternatively Known As: CHINT NM8N-250S-160/4/22, 160A 4P MCCB, 250A Frame Moulded Case Circuit Breaker
- Product Type: Moulded case circuit breaker
- Series: NM8N
- Frame Size: 250A
- Rated Current: 160A
- Number of Poles: 4P
- Trip Unit: Adjustable thermal-magnetic
- Overload Adjustment Range: 112–160A, 0.7–1.0 x In
- Magnetic Trip Setting: Fixed at 10 x In
- Breaking Capacity: 50kA at 380/400/415V AC
- Rated Operational Voltage: Up to 690V AC
- Rated Insulation Voltage: 1000V AC
- Rated Impulse Withstand Voltage: 8kV
- Neutral Protection: Protected neutral with phase-equivalent protection
- Frequency: 50/60Hz
- Mounting: Fixed type
- Utilisation Category: Category A
- Ingress Protection: IP40
- Mechanical Endurance: Up to 15,000 operating cycles
- Electrical Endurance: Up to 6,000 operating cycles
- Connection: Front connection with copper conductors or cable lugs
- Dimensions (H x L x W): 157mm x 140mm x 88.7mm
- Weight: 2.5 kg
- 50kA short-circuit breaking capacity at 380–415V AC
- Four-pole configuration for three-phase and neutral systems
- Adjustable thermal overload protection from 112A to 160A
- Thermal-magnetic protection for overload and short-circuit faults
- 250A frame accommodates a 160A rated current
- Protected neutral option supports comprehensive four-pole protection
- Suitable for fixed switchboard and power-distribution installations
- Accessory-compatible design with optional auxiliary, alarm, shunt and undervoltage releases
- Installation, testing and commissioning must be performed by a licensed electrician in accordance with AS/NZS 3000, the manufacturer's instructions and applicable switchboard requirements. Confirm prospective fault current, discrimination, cable sizing and local certification before installation.
- Switchboard mains protection
- Commercial and industrial power distribution
- Three-phase distribution boards with neutral protection
- Building services and plant switchboards
- Incoming protection for low-voltage distribution assemblies
- Overload and short-circuit protection for feeder circuits
- AS/NZS IEC 60947.2:2015 is the applicable Australian/New Zealand product standard for low-voltage circuit-breakers of this type
- AS/NZS 3000 applies to selection, installation and verification within Australian electrical installations
- Long mechanical and electrical service life can reduce replacement frequency and product waste
- Modular construction and compatible accessories can support repair or upgrading rather than complete replacement
- Metal and thermoplastic components may be recoverable through appropriate electrical equipment recycling channels
CHINT's general warranty policy for other low-voltage apparatus provides 27 months from the date of manufacture against defects in materials and workmanship when purchased through authorised sales channels; contract terms may vary.
Available through authorised CHINT distributors in Australia.