MCCB 4P 160A 70kA Thermal Magnetic 250A Frame NM8N Chint
Chint NM8N 160A 4P MCCB features 70kA breaking capacity, thermal-magnetic trip unit with protected neutral and a 250A frame. Ideal for switchboard mains protection.
Sign in
Please login to continue to your account.
Alternatively Known As: CHINT NM8N-250Q TM 160 4C, 160A 4P MCCB, 250AF Thermal-Magnetic Circuit Breaker, Moulded Case Circuit Breaker
- Product Type: Moulded case circuit breaker
- Series: NM8N-250Q
- Rated Current: 160 A
- Frame Size: 250 A
- Number of Poles: 4P
- Trip Unit: Thermal-magnetic
- Neutral Protection: Protected neutral pole
- Ultimate Breaking Capacity: 70 kA at AC 380/400/415 V
- Rated Operational Voltage: AC 380/400/415 V, 50/60 Hz
- Rated Insulation Voltage: 1000 V
- Rated Impulse Withstand Voltage: 8 kV
- Thermal Trip Setting: 0.7–1.0 × In
- Instantaneous Magnetic Trip Setting: 7–12 × In for 160 A
- Utilisation Category: A
- Isolation Suitable: Yes
- Mechanical Life: Up to 25,000 operating cycles
- Electrical Life: Up to 10,000 operating cycles at AC 415 V and rated current
- Mounting: Fixed or plug-in installation
- Dimensions (H x L x W): 157mm x 88.7mm x 140mm
- Weight: 2.5 kg
- 70 kA short-circuit breaking capacity at AC 380/400/415 V
- Four-pole construction for three-phase systems with neutral switching
- Protected neutral pole for enhanced four-wire circuit protection
- Thermal-magnetic trip unit for overload and short-circuit protection
- 250 A frame with 160 A rated current
- Suitable for switchboard mains and distribution protection
- Compatible with optional CHINT MCCB accessories
- Installation, testing and commissioning must be performed by a licensed electrician in accordance with AS/NZS 3000, the manufacturer's instructions and applicable switchboard requirements.
- Main incoming protection in commercial and industrial switchboards
- Three-phase distribution boards with neutral protection
- Building services and infrastructure power distribution
- Factory, plant and machinery supply protection
- High fault-level electrical distribution systems
- Applicable product standard: AS/NZS IEC 60947.2:2015 for low-voltage circuit-breakers
- Installation should comply with AS/NZS 3000 and applicable Australian electrical safety and equipment registration requirements
- Metallic and thermoplastic components can be separated for responsible recycling at end of service life
- Durable construction and high electrical endurance can reduce replacement frequency and product waste
- Fault protection helps limit damage to connected switchboard equipment and electrical assets
27 months from the date of manufacture for other CHINT low-voltage apparatus, subject to authorised sales channels, contract terms and applicable warranty conditions.
Available through authorised CHINT distributors in Australia.
