MCCB 4P 180A 100kA Thermal Magnetic 250A Frame NM8N Chint
Chint NM8N 180A 4P MCCB features 100kA breaking capacity, thermal-magnetic trip unit with protected neutral and a 250A frame. For switchboard mains protection.
Sign in
Please login to continue to your account.
Alternatively Known As: NM8N-250H TM 180 4P MCCB, 250A Frame MCCB, 4-Pole Moulded Case Circuit Breaker, Main Switchboard Circuit Breaker
- Frame Size: 250A
- Rated Current: 180A
- Number of Poles: 4P
- Trip Unit: Thermal-magnetic TM
- Neutral Protection: Protected neutral, 4C configuration
- Rated Ultimate Short-Circuit Breaking Capacity Icu: 100kA at AC 380/400/415V
- Rated Service Short-Circuit Breaking Capacity Ics: 100kA at AC 380/400/415V
- Rated Operational Voltage: Up to 690V AC
- Rated Insulation Voltage Ui: 1000V
- Rated Impulse Withstand Voltage Uimp: 8kV
- Frequency: 50/60Hz
- Utilisation Category: A
- Mounting: Fixed, plug-in or DIN rail mounting options subject to configuration
- Connection: Front or rear connection options subject to configuration
- Mechanical Life: Up to 25,000 operating cycles
- Electrical Life: Up to 10,000 operating cycles at AC 415V and rated current
- Suitable for Isolation: Yes
- Operating Temperature: -40°C to +70°C
- Dimensions (H x L x W): 157mm x 88.7mm x 140mm
- Weight: 2.5 kg
- High 100kA short-circuit breaking capacity at 400/415V AC
- Thermal-magnetic overload and short-circuit protection
- Four-pole switching for three-phase and neutral systems
- Protected neutral configuration for improved neutral conductor protection
- 250A frame accommodates a 180A rated current
- Suitable for switchboard mains and low-voltage power distribution
- Supports fixed and plug-in installation configurations
- Resettable protection reduces the need for replacement fuses
- Installation, testing and commissioning must be performed by a licensed electrician or suitably qualified switchboard professional in accordance with AS/NZS 3000, the manufacturer's instructions and applicable switchboard requirements.
- Main incoming protection in commercial switchboards
- Industrial power distribution boards
- Three-phase commercial and industrial electrical installations
- Data centre and critical power distribution systems
- Protection of feeders, busbars and downstream electrical equipment
- Applicable product standard: AS/NZS IEC 60947.2:2015 for low-voltage circuit-breakers
- Electrical installation and connection work should comply with AS/NZS 3000:2018
- Product documentation identifies compliance with IEC 60947-1 and IEC 60947-2
- RoHS documentation is available for the NM8N series, supporting restriction of hazardous substances
- Resettable circuit protection reduces consumable fuse waste
- Long mechanical and electrical service life can reduce replacement frequency and associated material waste
CHINT warranty policy provides 27 months from the date of manufacture for other low-voltage apparatus sold through authorised sales channels, subject to the applicable contract and warranty terms.
Available through authorised CHINT distributors in Australia.