MCCB 4P 180A 150kA Thermal Magnetic 250A Frame NM8N Chint
Chint NM8N 180A 4P MCCB features 150kA breaking capacity, thermal-magnetic trip unit with protected neutral and a 250A frame. For switchboard mains protection.
Sign in
Please login to continue to your account.
Alternatively Known As: CHINT NM8N 250R MCCB, 4P moulded case circuit breaker, 180A main circuit breaker, 150kA thermal-magnetic circuit breaker
- Rated Current: 180 A
- Frame Size: 250 A
- Number of Poles: 4P with protected neutral
- Trip Unit: Thermal-magnetic, TM type
- Ultimate Breaking Capacity Icu: 150 kA at 380–415 V AC
- Service Breaking Capacity Ics: 150 kA at 380–415 V AC
- Rated Operational Voltage: Up to 690 V AC
- Rated Insulation Voltage Ui: 1000 V
- Rated Impulse Withstand Voltage Uimp: 8 kV
- Thermal Trip Adjustment: 0.7–1.0 x In
- Magnetic Trip Adjustment: 5–10 x In for 180–250 A ratings
- Utilisation Category: A
- Mounting: Fixed installation
- Isolation: Suitable for isolation
- Terminal Tightening Torque: 11 Nm for M8 terminals
- Electrical Life: Up to 10,000 operations at 415 V AC and rated current
- Mechanical Life: Up to 25,000 operations
- Dimensions (H x L x W): 157mm x 88.7mm x 140mm
- Weight: 2.5 kg
- 150kA short-circuit breaking capacity at 380–415V AC
- Four-pole configuration with protected neutral
- Thermal-magnetic overload and short-circuit protection
- 250A frame with an 180A rated current
- Adjustable thermal and magnetic trip settings
- Suitable for main and distribution switchboard protection
- Designed for low-voltage commercial, industrial and building installations
- Suitable for vertical or horizontal installation with top or bottom line entry
- Installation, selection and commissioning must be performed by a licensed electrician in accordance with AS/NZS 3000, applicable switchboard requirements and CHINT installation instructions. Prospective fault current, discrimination, conductor sizing and enclosure suitability must be verified before installation.
- Switchboard mains protection
- Commercial and industrial electrical distribution
- Main incomer and sub-main protection
- Building services and plant distribution boards
- Data centre and infrastructure power distribution
- Low-voltage circuits requiring high short-circuit withstand capability
- IEC 60947-1 and IEC 60947-2 product standards apply to the NM8N MCCB range
- AS/NZS IEC 60947.2:2015 is the applicable Australian/New Zealand standard for low-voltage circuit-breakers
- Installation and switchboard integration should comply with AS/NZS 3000 and applicable switchboard standards
- Long mechanical and electrical service life can reduce replacement frequency and associated waste
- Copper, aluminium and steel components can be recovered for recycling at end of service life
- Thermal-magnetic protection helps limit damage to conductors and connected equipment during overload and short-circuit events
- Durable moulded-case construction supports extended service in commercial and industrial switchboards
CHINT warranty policy provides 27 months from the date of manufacture for other low-voltage apparatus sold through authorised sales channels, subject to the applicable customer contract and warranty conditions.
Available through authorised CHINT distributors in Australia.