MCCB 4P 180A 50kA Thermal Magnetic 250A Frame NM8N Chint
Chint NM8N 180A 4P MCCB features 50kA breaking capacity, thermal-magnetic trip unit with protected neutral and a 250A frame. Ideal for switchboard mains protection.
Sign in
Please login to continue to your account.
Alternatively Known As: CHINT NM8N-250S 4P MCCB, 180A moulded case circuit breaker, 50kA thermal-magnetic circuit breaker
- Breaker Type: Moulded case circuit breaker
- Poles: 4P with protected neutral
- Rated Current: 180A
- Frame Size: 250A
- Trip Unit: Adjustable thermal-magnetic
- Breaking Capacity: 50kA at 380/400/415V AC
- Rated Insulation Voltage Ui: 1000V AC
- Rated Impulse Withstand Voltage Uimp: 8kV
- Rated Operational Voltage: 380/400/415V AC, 50/60Hz
- Utilisation Category: Category A
- Trip Adjustment: Thermal 0.7–1.0 x In; magnetic 5–10 x In for 180–250A power-distribution models
- Installation Orientation: Vertical or horizontal, with top or bottom line entry
- Mechanical Life: Up to 25,000 operating cycles
- Electrical Life: Up to 10,000 operating cycles at 415V and rated current
- Standard Design Basis: IEC/EN 60947-2
- Dimensions (H x L x W): 157mm x 88.7mm x 140mm
- Weight: 2.5 kg
- Four-pole protection with protected neutral
- 50kA ultimate short-circuit breaking capacity at 380/400/415V AC
- Adjustable thermal-magnetic overload and short-circuit protection
- 250A frame with an 180A rated current
- Suitable for switchboard incomer, feeder and mains protection
- Can be installed vertically or horizontally
- Top or bottom line entry configuration
- Suitable for isolation when installed in accordance with applicable requirements
- Optional accessories and auxiliary devices are available for the NM8N series
- Installation, protection coordination and commissioning must be carried out by a licensed electrician in a de-energised switchboard, with conductor sizing, fault-level verification, neutral configuration and enclosure requirements assessed in accordance with AS/NZS 3000 and the applicable switchboard assembly requirements.
- Main switchboard incomer protection
- Commercial and industrial distribution boards
- Feeder protection in low-voltage switchboards
- Overload and short-circuit protection for three-phase systems with neutral
- Electrical distribution systems requiring high short-circuit withstand capability
- Designed to IEC/EN 60947-2, with AS/NZS IEC 60947.2:2015 being the applicable Australian/New Zealand circuit-breaker standard
- Installation should comply with AS/NZS 3000 Wiring Rules
- Switchboard integration should be assessed against the applicable AS/NZS 61439 assembly requirements
- RoHS documentation is available for the NM8N series to support control of restricted substances
- Long mechanical and electrical service life can reduce replacement frequency and equipment waste
- Metal and thermoplastic components may be separated for appropriate recycling at end of service life
CHINT's general warranty policy for other low-voltage apparatus provides 27 months from the date of manufacture against defects in materials and workmanship when purchased through authorised sales channels; contractual or Australian distributor terms may vary.
Available through authorised CHINT distributors in Australia.