MCCB 4P 200A 100kA Thermal Magnetic 250A Frame NM8N Chint
Chint NM8N 200A 4P MCCB features 100kA breaking capacity, thermal-magnetic trip unit with protected neutral and a 250A frame. For switchboard mains protection.
Sign in
Please login to continue to your account.
Alternatively Known As: CHINT NM8N-250H TM 4P 200A MCCB, 4-pole moulded case circuit breaker, 200A high-breaking-capacity circuit breaker
- Product Type: Moulded case circuit breaker
- Frame Size: 250A
- Rated Current: 200A
- Number of Poles: 4P
- Trip Unit: Thermal-magnetic, TM
- Breaking Capacity: 100kA at 380/400/415V AC
- Rated Operational Voltage: Up to 690V AC
- Rated Insulation Voltage Ui: 1000V
- Rated Impulse Withstand Voltage Uimp: 8kV
- Overload Setting: Adjustable from 0.7 to 1.0 x In
- Instantaneous Short-Circuit Setting: Adjustable from 5 to 10 x In for 180A to 250A power-distribution models
- Neutral Protection: Protected neutral pole
- Utilisation Category: A
- Isolation Function: Suitable for isolation
- Mechanical Life: Up to 25,000 operating cycles
- Electrical Life: Up to 10,000 cycles at 415V AC and rated current
- Installation Orientation: Vertical or horizontal mounting; top or bottom line entry
- Dimensions (H x L x W): 157mm x 88.7mm x 140mm
- Weight: 2.5 kg
- Four-pole protection for three-phase systems with neutral
- High 100kA short-circuit breaking capacity at 415V AC
- Adjustable thermal overload and magnetic short-circuit protection
- 250A frame with 200A rated current
- Protected neutral for enhanced four-wire system protection
- Suitable for switchboard mains and low-voltage distribution applications
- Compact moulded-case construction with fixed mounting configuration
- Compatible with selected CHINT accessories for indication, shunt trip and undervoltage release functions
- Installation, testing and commissioning must be performed by a licensed electrician in accordance with the manufacturer's instructions, applicable switchboard requirements and AS/NZS 3000. Confirm fault levels, discrimination, conductor capacity, terminal torque and required local certification before energising.
- Switchboard mains protection
- Commercial and industrial low-voltage distribution boards
- Three-phase building services and plant distribution
- Data centre and infrastructure power distribution
- Protection of large feeders and electrical equipment
- Industrial control panels and power-distribution assemblies
- Applicable product standard: AS/NZS 60947.2 for low-voltage circuit-breakers; confirm RCM status and local certification for the supplied CHINT variant before Australian installation
- Durable moulded-case construction can support extended service life and reduce replacement waste
- Metal terminals and conductive components can be recovered through appropriate electrical equipment recycling
- Supports safe, efficient electrical distribution and fault protection, helping reduce damage to downstream equipment
27 months from the date of manufacture for other CHINT low-voltage apparatus purchased through authorised sales channels, subject to applicable contract terms and warranty conditions.
Available through authorised CHINT distributors in Australia.