MCCB 4P 200A 150kA Thermal Magnetic 250A Frame NM8N Chint
Chint NM8N 200A 4P MCCB features 150kA breaking capacity, thermal-magnetic trip unit with protected neutral and a 250A frame. For switchboard mains protection.
Sign in
Please login to continue to your account.
Alternatively Known As: NM8N-250R-200/4/22, CHINT moulded case circuit breaker, 4-pole MCCB, 200 A high-breaking-capacity circuit breaker
- Product Configuration: NM8N-250R-200/4/22
- Device Type: Moulded case circuit breaker
- Number of Poles: 4P
- Rated Current: 200 A
- Frame Size: 250 A
- Trip Unit: Adjustable thermal-magnetic
- Neutral Protection: Protected neutral with adjustable settings
- Ultimate Breaking Capacity: 150 kA at 380/400/415 V AC
- Service Breaking Capacity: 150 kA at 380/400/415 V AC
- Rated Operational Voltage: 380/400/415 V, 440 V, 500 V and 660/690 V AC
- Rated Insulation Voltage: 1,000 V AC
- Rated Impulse Withstand Voltage: 8 kV
- Frequency: 50/60 Hz
- Utilisation Category: A
- Thermal Setting Range: 0.7–1.0 times rated current
- Magnetic Setting Range: 5–10 times rated current for 180–250 A distribution applications
- Installation Orientation: Vertical or horizontal mounting
- Electrical Life: Up to 10,000 operations at 415 V and rated current
- Mechanical Life: Up to 25,000 operations
- Dimensions (H x L x W): 157mm x 88.7mm x 140mm
- Weight: 2.5 kg
- 150 kA high ultimate and service short-circuit breaking capacity at 415 V AC
- Four-pole construction for three-phase and neutral switching
- Adjustable thermal overload and magnetic short-circuit protection
- Protected neutral with adjustable neutral protection settings
- 250 A frame with a 200 A rated trip current
- Suitable for switchboard mains and low-voltage power distribution protection
- Suitable for isolation when installed according to the applicable requirements
- Top or bottom line entry supported
- Optional auxiliary, alarm, shunt-trip and undervoltage accessories available for the NM8N series
- Installation, adjustment and commissioning must be performed by a licensed electrician in accordance with AS/NZS 3000, the manufacturer's instructions and the requirements for low-voltage switchgear. Confirm fault levels, discrimination, cable ratings and switchboard assembly compliance before installation.
- Main incoming protection in commercial and industrial switchboards
- Three-phase power distribution systems with neutral switching
- Low-voltage switchboard mains protection
- Industrial distribution boards and motor control centres
- High prospective-fault-current installations requiring up to 150 kA breaking capacity at 415 V AC
- Relevant product standard: AS/NZS IEC 60947.2:2015 for low-voltage circuit-breakers
- Manufacturer product documentation specifies IEC/EN 60947-2; Australian installation and switchboard compliance must be verified for the completed installation
- Durable moulded-case construction and a rated mechanical life of up to 25,000 operations can reduce replacement frequency and product waste
- Adjustable protection settings support accurate system coordination, helping reduce unnecessary equipment damage and replacement
- Designed for repairable and accessory-supported switchboard systems, extending functional service life
CHINT's general policy for other low-voltage apparatus provides a 27-month warranty from the date of manufacture against defects in materials and workmanship when supplied through authorised sales channels. Contract terms may vary.