MCCB 4P 200A 50kA Thermal Magnetic 250A Frame NM8N Chint
Chint NM8N 200A 4P MCCB features 50kA breaking capacity, thermal-magnetic trip unit with protected neutral and a 250A frame. Ideal for switchboard mains protection.
Sign in
Please login to continue to your account.
Alternatively Known As: CHINT NM8N 250S 4P MCCB, 4-pole moulded case circuit breaker, thermal-magnetic circuit breaker
- Product Type: Moulded case circuit breaker
- Rated Current: 200 A
- Frame Size: 250 A
- Number of Poles: 4P, protected neutral configuration
- Trip Unit: Adjustable thermal-magnetic release
- Ultimate Short-Circuit Breaking Capacity Icu: 50 kA at 380/400/415 V AC
- Service Short-Circuit Breaking Capacity Ics: 50 kA at 380/400/415 V AC
- Rated Operational Voltage: 380/400/415 V AC, with series ratings up to 690 V AC
- Rated Insulation Voltage Ui: 1000 V
- Rated Impulse Withstand Voltage Uimp: 8 kV
- Rated Frequency: 50/60 Hz
- Utilisation Category: A
- Isolation Suitability: Suitable for isolation
- Installation Orientation: Vertical or horizontal mounting; top or bottom line entry
- Dimensions (H x L x W): 157mm x 88.7mm x 140mm
- Weight: 2.5 kg
- 50 kA short-circuit breaking capacity at 380/400/415 V AC
- 4-pole construction with protected neutral
- Adjustable thermal-magnetic overload and short-circuit protection
- 250 A frame with a 200 A rated current
- Suitable for switchboards, distribution panels and feeder protection
- Supports fixed, plug-in and withdrawable installation configurations
- Designed for low-voltage power distribution applications
- Installation, selection, adjustment and commissioning should be carried out by a licensed electrical contractor in accordance with the manufacturer's instructions, AS/NZS 3000 and applicable switchboard requirements.
- Main switchboard protection
- Commercial and industrial distribution boards
- Feeder and sub-main protection
- Low-voltage power distribution systems
- Data centre and building services electrical systems
- AS/NZS IEC 60947.2:2015 – applicable product standard for low-voltage circuit-breakers
- AS/NZS 3000:2018 – electrical installation requirements applicable to installation and wiring
- Resettable circuit-breaker operation can reduce waste compared with repeated replacement of single-use fuses.
- Durable electrical protection supports extended equipment service life and helps reduce premature replacement of switchboard components.
27 months from the date of manufacture for other low-voltage apparatus sold through authorised channels, subject to applicable CHINT contract terms and exclusions.
Available through authorised CHINT distributors in Australia.