MCCB 4P 225A 100kA Thermal Magnetic 250A Frame NM8N Chint
Chint NM8N 225A 4P MCCB features 100kA breaking capacity, thermal-magnetic trip unit with protected neutral and a 250A frame. For switchboard mains protection.
Sign in
Please login to continue to your account.
Alternatively Known As: CHINT NM8N-250H TM 225 4C, 225A 4-pole moulded-case circuit breaker, 250A frame MCCB
- Circuit Breaker Type: Moulded-case circuit breaker for power distribution
- Frame Size: 250A
- Rated Current: 225A
- Number of Poles: 4P
- Neutral Protection: Protected neutral pole, 4C configuration
- Trip Unit: Thermal-magnetic, TM
- Ultimate Breaking Capacity: 100kA at 380–440V AC
- Service Breaking Capacity: 100kA at 380–440V AC
- Rated Operational Voltage: Up to 690V AC
- Rated Insulation Voltage: 1000V
- Rated Impulse Withstand Voltage: 8kV
- Frequency: 50/60Hz
- Thermal Adjustment: 0.7–1.0 times rated current
- Magnetic Adjustment: 5–10 times rated current for 180–250A distribution models
- Utilisation Category: A
- Installation: Fixed mounting with front connection
- Ingress Protection: IP40
- Operating Temperature: -40°C to +70°C
- Pollution Degree: 3
- Mechanical Endurance: 15,000 operations
- Electrical Endurance: Up to 6,000 operations at rated current
- Dimensions (H x L x W): 157mm x 88.7mm x 140mm
- Weight: 2.5 kg
- 100kA high short-circuit breaking capacity at common low-voltage distribution voltages
- Four-pole construction for three-phase and neutral switching
- Protected neutral pole for enhanced neutral conductor protection
- Thermal-magnetic trip unit for overload and short-circuit protection
- 250A frame accommodates rated currents from 125A to 250A
- Suitable for switchboard incomer and mains protection applications
- Fixed front-connection design for panel and switchboard installation
- Wide operating temperature range from -40°C to +70°C
- Installation, selection and commissioning must be carried out by a licensed electrician in accordance with the manufacturer's instructions, applicable switchboard requirements and AS/NZS 3000. Confirm fault levels, discrimination, cable ratings and required Australian approvals before energising.
- Switchboard mains protection
- Three-phase commercial and industrial distribution boards
- Low-voltage power distribution systems
- Main incomer protection for commercial buildings and industrial facilities
- Protection of feeders and busbar sections against overload and short circuit
- IEC/EN 60947-2 for low-voltage moulded-case circuit-breakers
- AS/NZS 3000:2018 for installation within Australian low-voltage electrical installations
- RoHS material compliance is declared for the NM8N product family
- Long mechanical and electrical service life can reduce replacement frequency and associated waste
- Thermal-magnetic protection helps prevent equipment damage and premature component replacement
CHINT's general warranty policy for low-voltage apparatus provides 27 months from the date of manufacture against defects in materials and workmanship when purchased through authorised sales channels; contractual or local distributor terms may differ.
Available through authorised CHINT distributors in Australia.