MCCB 4P 250A 150kA Thermal Magnetic 400A Frame NM8N Chint
Chint NM8N 250A 4P MCCB features 150kA breaking capacity, thermal-magnetic trip unit with protected neutral and a 400A frame. For switchboard mains protection.
Sign in
Please login to continue to your account.
Alternatively Known As: CHINT NM8N 400A Frame MCCB, 250A 4-Pole Moulded Case Circuit Breaker, 150kA MCCB with Protected Neutral
- Product Type: Moulded case circuit breaker
- Frame Size: 400A
- Rated Current: 250A
- Pole Configuration: 4P with protected neutral
- Trip Unit: Thermal-magnetic
- Ultimate Breaking Capacity Icu: 150kA at 380/415V AC
- Service Breaking Capacity Ics: 150kA at 380/415V AC
- Rated Operational Voltage: Up to 690V AC, 50/60Hz
- Rated Insulation Voltage Ui: 1000V
- Rated Impulse Withstand Voltage Uimp: 12kV
- Thermal Adjustment Range: 0.7–1.0 times rated current
- Magnetic Adjustment Range: 5–10 times rated current
- Utilisation Category: Category A
- Mounting: Fixed installation with front or rear connection
- Standard Product Series: NM8N-400R
- Dimensions (H x L x W): 255mm x 113mm x 185mm
- Weight: 6.7 kg
- 400A frame with a 250A adjustable thermal-magnetic trip unit
- Four-pole switching with protected neutral pole
- 150kA short-circuit breaking capacity at 380/415V AC
- Adjustable overload and instantaneous short-circuit protection
- Suitable for switchboard mains and high-fault-level distribution protection
- High insulation rating and impulse withstand capability
- Designed for commercial, industrial and infrastructure power distribution
- Installation, commissioning and adjustment must be performed by a licensed electrician or suitably qualified electrical contractor in accordance with applicable Australian wiring rules, switchboard requirements and the manufacturer's instructions.
- Switchboard mains protection
- Commercial and industrial power distribution
- Main incoming protection for high-fault-level installations
- Protection of feeders, busbars and large electrical equipment
- Four-wire three-phase systems requiring protected neutral switching
- AS/NZS IEC 60947.2 for low-voltage circuit-breakers
- RoHS-related compliance documentation is available for the NM8N product series, supporting reduced use of restricted hazardous substances
- Durable moulded-case construction and high mechanical life can reduce replacement frequency and material waste
- Adjustable protection settings can support efficient system coordination and help minimise unnecessary equipment damage
CHINT warranty policy provides 27 months from the date of manufacture for other low-voltage apparatus sold through authorised sales channels, subject to the applicable sales contract and warranty terms.
Available through authorised CHINT distributors in Australia.