MCCB 4P 250A 50kA Thermal Magnetic 250A Frame NM8N Chint
Chint NM8N 250A 4P MCCB features 50kA breaking capacity, thermal-magnetic trip unit with protected neutral and a 250A frame. Ideal for switchboard mains protection.
Sign in
Please login to continue to your account.
Alternatively Known As: Moulded Case Circuit Breaker, 4P MCCB, Thermal-Magnetic Circuit Breaker, NM8N-250S-250/4/22
- Frame Size: 250A
- Rated Current: 250A
- Number of Poles: 4P with protected neutral
- Trip Unit: Adjustable thermal-magnetic
- Breaking Capacity: 50kA at 380/400/415V AC
- Rated Operational Voltage: Up to 690V AC
- Rated Insulation Voltage: 1000V
- Rated Impulse Withstand Voltage: 8kV
- Overload Adjustment: 0.7–1.0 x In
- Magnetic Trip Adjustment: 5–10 x In for 180–250A distribution ratings
- Utilisation Category: A
- Isolation: Suitable for isolation
- Mechanical Life: 25,000 operating cycles
- Electrical Life: 10,000 operating cycles at 415V AC and rated current
- Product Standard: IEC 60947-2
- Dimensions (H x L x W): 157mm x 88.7mm x 140mm
- Weight: 2.5 kg
- Four-pole configuration with protected neutral
- 50kA short-circuit breaking capacity at typical low-voltage distribution voltages
- Adjustable thermal overload and magnetic short-circuit protection
- 250A frame with 250A rated current
- Suitable for switchboard mains and feeder protection
- Can be installed vertically or horizontally
- Top or bottom line entry supported
- Compatible with CHINT NM8N accessories and auxiliary components
- Installation, selection and commissioning must be performed by a licensed electrical professional in accordance with applicable wiring rules, fault-level calculations, manufacturer instructions and switchboard requirements. Verify that the product configuration and certification are suitable for the Australian installation before use.
- Main switchboard protection
- Commercial and industrial power distribution
- Low-voltage feeder protection
- Building services switchboards
- Data centre and infrastructure power distribution
- Overload and short-circuit protection for three-phase four-wire systems
- Designed to IEC 60947-2; AS/NZS IEC 60947.2:2015 is the applicable Australian/New Zealand circuit-breaker standard reference for this product category.
- RoHS declarations are available for the NM8N product family, supporting restriction of hazardous substances in manufacture
- Long mechanical and electrical service life can reduce replacement frequency and associated material waste
- Copper and aluminium components used in electrical switchgear are recyclable at end of service life
CHINT warranty policy states 27 months from the date of manufacture for other low-voltage apparatus sold through authorised sales channels, subject to the applicable contract and warranty terms.
Available through authorised CHINT distributors in Australia.