MCCB 4P 250A 70kA Standard Electronic 250A Frame NM8N Chint
Chint NM8N 250A 4P MCCB features 70kA breaking capacity, standard electronic trip unit with protected neutral and a 250A frame. For switchboard mains protection.
Sign in
Please login to continue to your account.
Alternatively Known As: CHINT NM8N 250A 4P MCCB, 250A Electronic Moulded Case Circuit Breaker, 70kA MCCB
- Series: NM8N
- Frame Size: 250A
- Rated Current: 250A
- Number of Poles: 4P
- Trip Unit: EM standard electronic release
- Breaking Capacity: 70kA at 380–440V AC; 40kA at 500V AC; 8kA at 660–690V AC
- Rated Operational Voltage: 380/400/415V, 440V, 500V, 660/690V AC, 50/60Hz
- Rated Insulation Voltage: 1000V
- Rated Impulse Withstand Voltage: 8kV
- Neutral Protection: Adjustable protected neutral pole
- Protection Functions: Long-time, short-time, instantaneous and earth-fault protection
- Installation: Fixed mounting with top or bottom line entry; vertical or horizontal installation
- Compliance: IEC/EN 60947-1, IEC/EN 60947-2 and IEC/EN 60947-3
- Dimensions (H x L x W): 157mm x 88.7mm x 140mm
- Weight: 2.65 kg
- 250A rated current with a 250A frame size
- Four-pole configuration for three-phase and neutral switching
- 70kA ultimate and service short-circuit breaking capacity at 380–440V AC
- Standard EM electronic trip unit with adjustable protection parameters
- Four-stage protection including earth-fault protection
- Real-time current display on the electronic trip unit
- Adjustable neutral-line protection
- Suitable for switchboard mains and low-voltage power distribution
- Optional auxiliary, shunt, undervoltage and motor-operating accessories
- Installation, commissioning and protection-setting adjustments must be performed by a licensed electrical contractor in accordance with AS/NZS 3000, the manufacturer's instructions and the requirements applicable to the switchboard assembly. Verify prospective fault current, discrimination, cable capacity and local RCM requirements before energisation.
- Main incoming protection in commercial and industrial switchboards
- Low-voltage power distribution systems
- Building services and plant-room electrical distribution
- Protection of feeders, busbars and large electrical loads
- Three-phase systems requiring switched and protected neutral conductors
- AS/NZS 60947.2: Low-voltage switchgear and controlgear — Circuit-breakers; verify certification for the supplied Australian-market variant
- AS/NZS 3000: Electrical installations, including switchboard installation and wiring requirements
- IEC/EN 60947-2 product testing and performance standard
- Electronic protection improves protection accuracy and may reduce nuisance tripping and associated equipment replacement
- RoHS documentation is available for the NM8N product family, supporting restricted-substance compliance
- Reusable electrical and metal components can be separated for recycling at end of service life
- Durable moulded-case construction supports a long service life and reduces replacement waste
CHINT warranty policy specifies 27 months from the date of manufacture for other low-voltage apparatus sold through authorised sales channels, subject to the applicable contract and warranty conditions.
Available through authorised CHINT distributors in Australia.