MCCB 4P 350A 36kA Thermal Magnetic 400A Frame NM8N Chint
Chint NM8N 350A 4P MCCB features 36kA breaking capacity, thermal-magnetic trip unit with protected neutral and a 400A frame. Ideal for switchboard mains protection.
Sign in
Please login to continue to your account.
Alternatively Known As: Moulded Case Circuit Breaker, MCCB, Thermal-Magnetic Circuit Breaker, NM8N-400C TM 350A 4P
- Series: NM8N
- Rated Current: 350A
- Number of Poles: 4P
- Frame Rating: 400A
- Trip Unit: Thermal-magnetic
- Breaking Capacity: 36kA at 380/400/415V AC
- Rated Operational Voltage: 380/400/415V AC, maximum 690V AC
- Rated Insulation Voltage: 1000V AC
- Rated Impulse Withstand Voltage: 8kV
- Thermal Adjustment Range: 0.7–1.0 x In
- Utilisation Category: A
- Neutral Protection: Protected neutral pole
- Isolation Suitability: Suitable for isolation
- Mechanical Life: Up to 15,000 operating cycles
- Electrical Life: Up to 10,000 operating cycles at 415V AC
- Dimensions (H x L x W): 255mm x 185mm x 113mm
- Weight: 7 kg
- Four-pole configuration for three-phase and neutral circuit protection
- Thermal-magnetic trip unit for overload and short-circuit protection
- 36kA ultimate short-circuit breaking capacity at 380/400/415V AC
- 400A frame accommodates rated currents up to 400A
- Protected neutral for comprehensive switchboard protection
- Adjustable thermal trip setting from 70% to 100% of rated current
- Suitable for switchboard mains and feeder protection
- Front connection fixed MCCB design
- Installation, adjustment and commissioning should be performed by a licensed electrical contractor in accordance with the manufacturer's instructions and applicable Australian wiring requirements. De-energise and verify isolation before installation or maintenance.
- Main switchboard protection
- Commercial and industrial distribution boards
- Three-phase feeder protection
- Large HVAC and mechanical services switchboards
- Motor and equipment feeder protection where the thermal-magnetic characteristics are suitable
- Overload and short-circuit protection for low-voltage distribution circuits
- AS/NZS IEC 60947.2:2015 for low-voltage circuit-breakers
- Long operating life can reduce replacement frequency and associated material waste
- Metal components such as copper and steel can generally be recovered through appropriate electrical equipment recycling streams
- Overload and short-circuit protection helps limit damage to downstream electrical equipment, reducing premature replacement
CHINT warranty policy provides 27 months from the date of manufacture for other low-voltage apparatus sold through authorised channels, subject to the applicable contract and warranty conditions.
Available through authorised CHINT distributors in Australia.