MCCB 4P 350A 50kA Thermal Magnetic 400A Frame NM8N Chint
Chint NM8N 350A 4P MCCB features 50kA breaking capacity, thermal-magnetic trip unit with protected neutral and a 400A frame. Ideal for switchboard mains protection.
Sign in
Please login to continue to your account.
Alternatively Known As: 350A 4P Moulded Case Circuit Breaker, NM8N 400A Frame MCCB, Thermal Magnetic MCCB, Main Switchboard Circuit Breaker
- Product Type: Moulded case circuit breaker
- Frame Size: 400A frame, Frame 23
- Rated Current: 350A at 40°C
- Number of Poles: 4P
- Trip Unit: Thermal-magnetic, electromechanical
- Neutral Protection: Protected neutral pole
- Breaking Capacity Icu: 50kA at AC 380/400/415V
- Service Breaking Capacity Ics: 50kA at AC 380/400/415V
- Rated Operational Voltage Ue: Up to 690V AC
- Rated Insulation Voltage Ui: 1000V AC
- Rated Impulse Withstand Voltage Uimp: 8kV
- Frequency: 50/60Hz
- Adjustable Current Range: 0.7–1.0 x In
- Utilisation Category: Category A
- Ingress Protection: IP00, or IP40 with terminal covers
- Power Dissipation: 122.4W
- Electrical Durability: 1,500 operations
- Mechanical Durability: 15,000 operations
- Dimensions (H x L x W): 255mm x 185mm x 113mm
- Weight: 5.5 kg
- 50kA short-circuit breaking capacity at 380/400/415V AC
- Four-pole configuration with protected neutral
- Thermal-magnetic overload and short-circuit protection
- 400A frame with 350A rated current
- Adjustable thermal trip range from 70% to 100% of rated current
- Suitable for switchboard mains and industrial power distribution
- Accessory-ready design for compatible auxiliary and shunt-release accessories
- Installation, testing and commissioning must be carried out by a licensed electrician in accordance with the manufacturer's instructions, applicable switchboard requirements and AS/NZS 3000. Confirm fault levels, discrimination, conductor sizing, termination torque and Australian certification requirements before energising.
- Main switchboard incoming protection
- Industrial power distribution boards
- Commercial building switchboards
- Power centres and motor control centres
- Overload and short-circuit protection for three-phase electrical installations
- Product documentation references IEC/EN 60947-2 for low-voltage circuit-breakers
- Applicable Australian/New Zealand product standard: AS/NZS IEC 60947.2:2015
- Installation and verification should comply with AS/NZS 3000, including local certification and RCM requirements where applicable
- Durable moulded-case construction supports extended service life and reduces replacement waste
- Metal components can be recovered through appropriate electrical equipment recycling at end of life
- Resettable circuit protection helps limit damage and replacement of downstream electrical equipment
CHINT's general warranty policy lists 27 months from the date of manufacture for other low-voltage apparatus sold through authorised channels; contract terms or local distributor conditions may vary.
Available through authorised CHINT distributors in Australia.