MCCB 4P 350A 70kA Thermal Magnetic 400A Frame NM8N Chint
Chint NM8N 350A 4P MCCB features 70kA breaking capacity, thermal-magnetic trip unit with protected neutral and a 400A frame. Ideal for switchboard mains protection.
Sign in
Please login to continue to your account.
Alternatively Known As: Moulded Case Circuit Breaker, MCCB, Thermal-Magnetic Circuit Breaker, 4P Main Circuit Breaker
- Product Series: NM8N-400Q
- Circuit Breaker Type: Moulded case circuit breaker
- Number of Poles: 4P
- Rated Current: 350A
- Frame Size: 400A
- Trip Unit: Adjustable thermal-magnetic
- Ultimate Breaking Capacity: 70kA at 380/400/415V AC
- Service Breaking Capacity: 70kA at 380/400/415V AC
- Rated Operational Voltage: 380/415V AC
- Maximum Operational Voltage: 690V AC
- Rated Insulation Voltage: 1,000V AC
- Rated Impulse Withstand Voltage: 8kV
- Adjustable Thermal Current Range: 245–350A
- Adjustable Magnetic Trip Range: 1,750–3,500A
- Utilisation Category: Category A
- Ingress Protection: IP00; IP40 with terminal covers
- Installation: Fixed mounting with front or rear connection options
- Dimensions (H x L x W): 255mm x 113mm x 185mm
- Weight: 5.5 kg
- Four-pole protection for three-phase systems with neutral switching
- Protected neutral configuration
- 70kA short-circuit breaking capacity at 380–415V AC
- Adjustable thermal and magnetic trip settings
- 400A frame accommodates ratings from 250A to 400A
- Suitable for switchboard mains and low-voltage distribution protection
- Can be installed with line or load connections at the top or bottom
- Compatible with selected auxiliary and operating accessories
- Installation, commissioning and testing must be performed by a licensed electrician in accordance with applicable Australian wiring rules, manufacturer instructions and switchboard requirements. Confirm fault levels, discrimination, cable capacity and neutral configuration before installation.
- Switchboard mains protection
- Commercial and industrial low-voltage distribution boards
- Power centres and main distribution boards
- Motor control centres and industrial plant distribution
- Protection of feeders, cables and electrical equipment against overload and short circuit
- AS/NZS IEC 60947.2 for low-voltage circuit-breakers
- Durable moulded-case construction can support extended service life and reduce replacement waste
- Metal terminals and internal conductive materials are recoverable through appropriate electrical equipment recycling streams
- Adjustable protection settings can help coordinate system protection and limit unnecessary equipment damage
CHINT warranty policy for other low-voltage apparatus provides 27 months from the date of manufacture against defects in materials and workmanship when supplied through authorised sales channels; contract terms may vary.