MCCB 4P 400A 100kA Thermal Magnetic 400A Frame NM8N Chint
Chint NM8N 400A 4P MCCB features 100kA breaking capacity, thermal-magnetic trip unit with protected neutral and a 400A frame. For switchboard mains protection.
Sign in
Please login to continue to your account.
Alternatively Known As: CHINT NM8N-400H TM MCCB, 4P 400A moulded case circuit breaker, 100kA MCCB
- Product Type: Moulded case circuit breaker
- Frame Size: 400A
- Rated Current: 400A
- Number of Poles: 4P with protected neutral
- Trip Unit: Adjustable thermal-magnetic TM
- Breaking Capacity: 100kA at 380–415V AC
- Rated Operational Voltage: Up to 690V AC, 50/60Hz
- Rated Insulation Voltage: 1000V
- Rated Impulse Withstand Voltage: 8kV
- Utilisation Category: A
- Connection: Fixed front or rear connection; plug-in options available
- Mechanical Life: Up to 25,000 operating cycles
- Electrical Life: Up to 10,000 cycles at 415V AC and rated current
- Manufacturer Product Standard: IEC/EN 60947-2
- Dimensions (H x L x W): 157mm x 88.7mm x 140mm
- Weight: 2.5 kg
- 100kA ultimate and service short-circuit breaking capacity at 380–415V AC
- Four-pole configuration with protected neutral
- Adjustable thermal overload and magnetic short-circuit protection
- 400A frame with adjustable current settings
- Suitable for switchboard mains and low-voltage power distribution protection
- Suitable for isolation
- Can be installed vertically or horizontally
- Compatible with optional auxiliary, shunt-release, undervoltage and motorised operating accessories
- Installation, configuration and testing must be performed by a licensed electrical professional in accordance with AS/NZS 3000, the switchboard design requirements and the manufacturer's instructions.
- Switchboard mains protection
- Low-voltage commercial and industrial power distribution
- Main incoming protection for distribution boards
- Protection of feeders and large electrical loads
- Electrical installations requiring high fault-level interruption capacity
- Applicable product standard: AS/NZS IEC 60947.2:2015 for low-voltage circuit-breakers
- Installation should comply with AS/NZS 3000 Wiring Rules
- Verify local Australian approval, RCM requirements and fault-rating suitability before installation
- Durable moulded-case construction can provide a long service life and reduce replacement waste
- Metal and thermoplastic components may be recoverable through appropriate electrical equipment recycling streams
- Protects downstream equipment from overload and short-circuit damage, helping reduce premature equipment replacement