MCCB 4P 63A 70kA Standard Electronic 250A Frame NM8N Chint
Chint NM8N 63A 4P MCCB features 70kA breaking capacity, standard electronic trip unit with protected neutral and a 250A frame. For switchboard mains protection.
Sign in
Please login to continue to your account.
Alternatively Known As: CHINT NM8N 4P MCCB, 63A Moulded Case Circuit Breaker, 70kA Electronic MCCB, Protected Neutral MCCB
- Product Series: NM8N
- Frame Size: 250A
- Rated Current: 63A
- Poles: 4P
- Trip Unit: Standard electronic EN type
- Neutral Protection: Protected neutral pole
- Ultimate Breaking Capacity: 70kA at 380/400/415V AC
- Service Breaking Capacity: 70kA at 380/400/415V AC
- Rated Insulation Voltage Ui: 1000V AC
- Rated Impulse Withstand Voltage Uimp: 8kV
- Rated Operational Voltage Ue: 380/400/415V, 440V, 500V and 660/690V AC, subject to breaking-capacity derating
- Rated Short-Time Withstand Current Icw: 1kA for 1 second at 63A
- Utilisation Category: A
- Connection: Fixed front or rear connection
- Ambient Operating Temperature: -25°C to +70°C for standard electronic release
- Mechanical Life: Up to 25,000 operating cycles
- Electrical Life: Up to 10,000 operating cycles at 415V AC and rated current
- Applicable Product Standard: IEC/EN 60947-2
- Dimensions (H x L x W): 157mm x 88.7mm x 140mm
- Weight: 2.65 kg
- Four-pole MCCB for three-phase systems with neutral protection
- 70kA short-circuit breaking capacity at common low-voltage operating voltages
- Standard electronic trip unit for adjustable overload and short-circuit protection
- 250A frame with a 63A rated current
- Suitable for switchboard mains and distribution protection
- Suitable for isolation when installed and operated in accordance with the manufacturer’s instructions
- Zero-arc-distance design
- Fixed mounting with front or rear connection options
- Installation, testing and commissioning should be performed by a licensed electrician in accordance with AS/NZS 3000, applicable switchboard requirements and the manufacturer’s instructions. Confirm fault level, voltage, discrimination, cable capacity and required local approvals before installation.
- Main incoming protection in low-voltage switchboards
- Commercial and industrial distribution boards
- Three-phase mains protection with protected neutral
- High fault-level power distribution systems
- Electrical equipment and submain protection
- AS/NZS IEC 60947.2:2015 is the applicable Australian and New Zealand standard for low-voltage circuit-breakers; verify product marking and local approval requirements before installation
- AS/NZS 3000 applies to electrical installation, wiring and switchboard integration
- Electronic trip protection can help reduce unnecessary equipment replacement by providing controlled overload and short-circuit protection
- Durable moulded-case construction and high operating life can reduce replacement frequency and associated material waste
- Metal and thermoplastic components may be recoverable through appropriate electrical equipment recycling streams at end of life
CHINT’s general warranty policy for other low-voltage apparatus provides coverage against defects in materials and workmanship for 27 months from the date of manufacture when supplied through authorised sales channels; contract terms may vary.
Available through authorised CHINT distributors in Australia.