Online UPS 10kVA 8kW 1Ph with 32x120Ah Batteries PowerSeries
PowerSeries GP online double conversion UPS features 10kVA 8kW, 1:1 single phase, 32x120Ah battery bank and generator compatibility. Ideal for critical loads.
Sign in
Please login to continue to your account.
Alternatively Known As: 10kVA Online UPS, 8kW Single-Phase UPS, GP810 UPS, PowerSeries GP UPS, 192V VRLA Battery Backup System
- UPS Model: GP810
- Capacity: 10kVA / 8kW
- Topology: True online double conversion
- Phase Configuration: Single-phase input and output, 1:1
- Output Voltage: 230V nominal
- Output Waveform: Pure sine wave
- Output Power Factor: 0.8
- Battery Bank: 32 x 12V 120Ah sealed lead-acid batteries
- Battery System Voltage: 192V DC
- Battery Arrangement: Two A16 battery cabinets
- Battery Type: Valve-regulated, sealed lead-acid, maintenance-free
- Input Voltage Range: 176-264V AC
- Input Frequency Range: 40-60Hz
- Output Voltage Regulation: ±1%
- Output Distortion: Less than 3% with linear load
- Transfer Time: 0 seconds in online mode
- Efficiency: Greater than 85%
- Noise Level: Less than 58dB at 1m
- Operating Temperature: 0°C to 40°C
- Relative Humidity: 0-90%, non-condensing
- Communications: RS-232
- Installation: Onsite battery cabinet assembly required
- Dimensions (H x L x W): 867mm x 650mm x 497mm
- Weight: 1270 kg
- True online double-conversion operation for continuous power conditioning
- Transformer-based galvanic isolation between input and output
- 10kVA capacity with 8kW active power output
- Single-phase 1:1 configuration for critical electrical loads
- Pure sine-wave output suitable for sensitive electronic and inductive equipment
- Generator compatible for extended backup-power applications
- Zero transfer time between mains and battery operation
- Expandable backup time with external battery configuration
- LCD and LED status indication for input, output, bypass, battery and fault conditions
- Protection against overload, short circuit, over-temperature and input surges
- Advanced battery management with automatic charging in off mode
- Installation, battery connection, commissioning and hardwired electrical work should be completed by a licensed electrical contractor or suitably qualified UPS technician in accordance with the manufacturer's instructions, AS/NZS 3000 and applicable UPS safety requirements. The battery cabinets require onsite assembly and the battery bank contains hazardous DC voltages.
- Data centres and server rooms
- Telecommunications and network infrastructure
- Industrial control and automation systems
- Security, surveillance and access-control systems
- Point-of-sale and computer systems
- Medical and other critical electronic loads
- Inductive loads including motors, air-conditioning equipment and compressors
- Critical loads requiring generator-compatible extended backup
- AS 62040.1:2019 - Uninterruptible power systems, general and safety requirements
- AS IEC 62040.2 - Uninterruptible power systems, electromagnetic compatibility requirements
- AS IEC 62040.3 - Uninterruptible power systems, performance and test requirements
- AS/NZS 3000 - Electrical installations and wiring requirements for permanent UPS installation
- Sealed lead-acid batteries are replaceable and recyclable through approved battery-recycling channels
- Long-life transformer-based construction and replaceable battery modules can reduce equipment replacement and electronic waste
- Generator compatibility can support efficient integration with standby power systems and reduce interruption-related equipment losses
PSS standard return-to-base warranty: 2 years from the purchase date for faults in materials or workmanship, subject to correct installation, commissioning, operating conditions and proof of purchase. Battery warranty coverage may be subject to separate battery terms and operating conditions.
Available through PowerSeries/PSS and authorised Australian distributors; contact the distributor for current stock, lead time and quotation.
UPS Sizing Calculator
This calculator follows relevant Australian standards to ensure reliable and compliant performance. It provides an estimated recommendation based on user inputs.
Users must verify specifications before purchasing.