Technical Specifications
  • Model: GP810-120-48
  • Rated Capacity: 10kVA / 8kW
  • Topology: Online double conversion with transformer and galvanic isolation
  • Phase Configuration: Single phase input and output, 1:1
  • Input Voltage Range: 176–264V AC
  • Input Frequency Range: 40–60Hz
  • Output Voltage: 230V AC ±1%
  • Output Frequency: 50Hz ±0.5%
  • Output Waveform: PWM sine wave
  • Output Power Factor: 0.8
  • Output Harmonic Distortion: Less than 3% at linear load
  • Battery Configuration: 48 x 12V 120Ah sealed lead-acid batteries
  • Battery System Voltage: 192V DC
  • Battery Type: Sealed lead-acid, maintenance-free
  • Battery Recharge Time: Approximately 8 hours to 90% capacity after complete discharge
  • Transfer Time: 0 seconds
  • Generator Compatibility: Yes
  • Communications: RS232 and relay contact output; optional SNMP monitoring
  • Display: LCD and LED mimic panel
  • Protection: Input surge filtering, electronic and fuse protection, overload, over-temperature and short-circuit protection
  • Operating Temperature: 0–40°C
  • Operating Humidity: 0–90% RH, non-condensing
  • Noise Level: Less than 58dB
  • UPS Unit Dimensions: 867H x 305W x 650D mm
  • UPS Unit Weight Without Batteries: 182kg
  • Battery Cabinet Configuration: Three external battery cabinets, 16 x 120Ah batteries per cabinet
  • Battery Bank Dimensions: 1230H x 780W x 1460D mm
  • Battery Bank Weight: 1626kg
  • Dimensions (H x L x W): 1230mm x 1460mm x 780mm
  • Weight: 1808 kg
Key Features
  • True online double-conversion power protection for critical loads
  • 10kVA capacity with 8kW active power output
  • Single-phase 1:1 configuration suitable for commercial and industrial applications
  • 192V DC battery system using 48 x 120Ah sealed lead-acid batteries
  • Generator-compatible operation
  • Galvanic isolation through transformer-based design
  • Pure sine-wave PWM output with less than 3% THD at linear load
  • Zero transfer time during mains failure
  • LCD and LED status indication for voltage, frequency, battery status, load and temperature
  • Manual and static bypass functionality
  • Expandable communications with optional SNMP remote monitoring
  • Integrated overload, short-circuit and over-temperature protection
Professional Installation Requirements
  • Installation, battery connection, commissioning and maintenance must be performed by a suitably qualified electrical contractor or approved PSS technician. The hardwired UPS must be commissioned in accordance with the manufacturer's instructions and applicable Australian electrical and battery-installation requirements, including AS/NZS 3000 and AS/NZS 5139 where applicable.
Applications
  • Data centres and server rooms
  • Telecommunications infrastructure
  • Industrial control systems
  • Security and surveillance systems
  • Point-of-sale and retail systems
  • Telephone and communications systems
  • Gates and access-control systems
  • Other critical loads requiring extended backup runtime
Standards & Compliance
  • AS IEC 62040.1: Uninterruptible power systems — general and safety requirements
  • AS IEC 62040.2: Uninterruptible power systems — electromagnetic compatibility requirements
  • AS IEC 62040.3: Uninterruptible power systems — method of specifying performance and test requirements
  • AS/NZS 3000: Electrical installations — Wiring Rules
  • AS/NZS 5139: Electrical installations — safety of battery systems for use with power conversion equipment, where applicable
Environmental Benefits
  • Sealed lead-acid batteries are recoverable through established battery recycling schemes when replaced
  • Online power conditioning can reduce stress on connected equipment and help extend equipment service life
  • Replaceable external battery cabinets allow battery servicing without replacing the UPS power electronics
  • Generator compatibility supports integration with existing backup-power infrastructure
Warranty Information

PSS standard return-to-base warranty: 2 years from the purchase date for faults in materials or workmanship, subject to installation, commissioning, operating-condition and maintenance requirements. Hardwired products must be commissioned by an approved and authorised PSS technician or contractor within four weeks of invoicing to maintain warranty coverage.

Available Now

Available through PowerSeries/PSS and authorised Australian distributors; contact the distributor for current stock, configuration and delivery information.


UPS Sizing Calculator




This calculator follows relevant Australian standards to ensure reliable and compliant performance. It provides an estimated recommendation based on user inputs.