Online UPS 4kVA 3.2kW 1Ph Excluding Batteries PowerSeries
PowerSeries GP online UPS features 4kVA 3.2kW, 1:1 single phase, expandable backup and generator compatibility. Ideal for critical loads; batteries not included.
Sign in
Please login to continue to your account.
Alternatively Known As: GP804 Online UPS, GP Series 4kVA UPS, 4kVA Double-Conversion UPS, PowerSeries GP804
- Model: GP804
- Capacity: 4kVA / 3.2kW
- Configuration: 1:1 single phase input and output
- Topology: True online double conversion
- Output Waveform: Pure sine wave
- Isolation: Galvanic isolation via transformer-based design
- Inverter: IGBT with sine wave PWM
- Output Voltage: 230V AC nominal
- Output Distortion: Less than 3% THD for linear loads
- Battery Configuration: External batteries required; batteries not included
- Battery Voltage: 192V DC nominal
- Transfer Time: Zero in online-to-battery operation
- Communications: RS-232; optional monitoring and SNMP accessories
- Operating Temperature: 0°C to 40°C
- Relative Humidity: 0% to 90% non-condensing
- Noise Level: Less than 58dB at 1 metre
- Connection: Input and output terminal block
- Dimensions (H x L x W): 700mm x 580mm x 230mm
- Weight: 102 kg
- True online double-conversion protection for critical loads
- 3.2kW active power capacity from a 4kVA UPS rating
- Galvanic isolation for improved load protection
- Generator-compatible design
- Expandable backup time using external battery banks
- Pure sine wave output suitable for sensitive and induction loads
- Zero transfer time between mains and battery operation
- LED and LCD status and load monitoring
- Manual bypass and protection against overload and UPS faults
- Battery-free supply allows the battery bank to be selected separately
- Installation, battery connection, commissioning and servicing should be performed by a licensed electrical contractor or suitably qualified UPS technician. The unit uses hardwired input and output terminals and a high-voltage external battery system. Installation must comply with the manufacturer's instructions and applicable Australian electrical requirements, including AS/NZS 3000.
- Data and server rooms
- Telecommunications systems
- Industrial control and automation equipment
- Security and surveillance systems
- Point-of-sale equipment
- Computer and network infrastructure
- Gate and access-control systems
- Critical loads requiring generator compatibility and extended runtime
- AS 62040.1:2019 - Uninterruptible power systems safety requirements, applicable to UPS equipment
- AS 62040.3 - Uninterruptible power systems performance and test requirements
- AS/NZS 3000 - Electrical installations, applicable to fixed electrical installation and wiring work
- Expandable external battery architecture allows battery capacity to be matched to the required runtime, avoiding unnecessary battery material use
- External battery replacement can extend the service life of the UPS and reduce whole-unit replacement waste
- Transformer-based construction and a stated long service-life design can reduce replacement frequency
- Sealed lead-acid battery banks, when selected, should be recycled through an approved battery recycling programme at end of life
PSS standard return-to-base warranty terms state a 2-year warranty against defects in materials and workmanship for eligible PSS-manufactured products, subject to proof of purchase, correct installation and operating conditions. Confirm the applicable warranty for the PowerSeries GP804 at order placement; batteries may be covered under separate terms.
Available through Australian electrical, power-protection and authorised distribution channels; battery bank and associated accessories are supplied separately.
UPS Sizing Calculator
This calculator follows relevant Australian standards to ensure reliable and compliant performance. It provides an estimated recommendation based on user inputs.
Users must verify specifications before purchasing.