SCHNAP Logo

Making Trade Life Easy!
Trade Discount 25%

Online UPS 6kVA 4.8kW 1Ph with 32x120Ah Batteries PowerSeries

BRAND: CABAC
SKU: GP806-120-32
$34,280.00 List price: $45,706.60
Free pick up (over 25 kg or over 1 meter)
Contact us for delivery cost
PowerSeries GP online double conversion UPS features 6kVA 4.8kW, 1:1 single phase, 32x120Ah battery bank and generator compatibility. Ideal for critical loads.

Alternatively Known As: 6kVA Online UPS, 6kVA Single-Phase UPS, Double-Conversion UPS, Long-Run UPS with External Battery Bank

Technical Specifications
  • UPS Topology: Online double conversion
  • Rated Capacity: 6kVA
  • Rated Active Power: 4.8kW
  • Input/Output Configuration: 1:1 single phase
  • Battery Bank: 32 x 12V 120Ah sealed lead-acid batteries
  • Assumed Battery Arrangement: 16 batteries in series per string, with two parallel strings; verify before installation
  • Nominal DC Battery Voltage: Approximately 192V DC
  • Approximate Battery Energy: 23.04kWh nominal before discharge and efficiency losses
  • Generator Compatibility: Yes
  • Output Waveform: Pure sine wave
  • Transfer Time: Zero interruption in online mode
  • Battery Type: Valve-regulated lead-acid (VRLA/AGM), subject to supplied battery model
  • Communications: Confirm available RS232, USB, relay or SNMP interfaces with supplier
  • Dimensions Basis: Complete system dimensions are estimated from comparable 6kVA UPS and 120Ah VRLA battery cabinets; confirm against the supplier's installation drawing
  • Dimensions (H x L x W): 1200mm x 1000mm x 800mm
  • Weight: 1200 kg
Key Features
  • Online double-conversion power conditioning for critical loads
  • 6kVA capacity with 4.8kW rated output
  • Single-phase input and output configuration
  • Large external battery bank for extended runtime
  • 32 x 120Ah battery configuration
  • Compatible with generator-backed installations
  • Suitable for continuous protection of critical electrical and electronic loads
  • Sealed VRLA battery technology reduces routine electrolyte maintenance
  • Zero-transfer-time operation during mains failure
Professional Installation Requirements
  • Installation, commissioning and battery connection must be performed by a licensed electrical contractor and suitably qualified UPS technician. Provide appropriate isolation, earthing, ventilation, battery protection, cable sizing and emergency procedures in accordance with AS/NZS 3000 and the applicable AS 62040 series requirements. The 32-battery bank is heavy and should be installed in a purpose-designed battery cabinet or rack with suitable floor loading and access provisions.
Applications
  • Server rooms and data centres
  • Telecommunications and network infrastructure
  • Industrial control systems
  • Security, surveillance and access-control systems
  • Medical, laboratory and other critical electronic loads
  • Manufacturing and process-control equipment
  • Remote sites requiring generator-compatible backup power
Standards & Compliance
  • AS 62040.1:2019 — Uninterruptible power systems, general and safety requirements; applicable UPS safety standard in Australia. ([eess.gov.au](https://www.eess.gov.au/wp-content/uploads/2020/07/20-006-General-guidance-Standards-for-portable-UPS-devices-1.pdf?utm_source=openai))
  • AS/NZS 3000:2018 — Electrical installations, including wiring, isolation and earthing requirements for permanent installation. ([ups.services](https://ups.services/standards?utm_source=openai))
  • AS IEC 62040.3 — UPS performance and test requirements; verify the exact declared performance classification with the supplier. ([ups.services](https://ups.services/resources/how-to-size-a-ups?utm_source=openai))
  • AS/NZS 5139 may apply to the associated stationary battery installation depending on the battery system configuration and installation conditions; obtain an engineering assessment before installation. ([ups.services](https://ups.services/resources/how-to-size-a-ups?utm_source=openai))
Environmental Benefits
  • VRLA batteries are recyclable through approved battery-recycling channels, supporting recovery of lead and other materials
  • Online double-conversion operation can improve power quality and reduce losses associated with voltage disturbances and equipment downtime
  • Generator compatibility can support efficient operation of standby-generation systems when correctly configured
  • Replaceable battery-bank design can extend the service life of the UPS electronics and reduce whole-system replacement waste
  • Sealed battery construction reduces the risk of electrolyte spills during normal operation
Warranty Information

A specific POWERSERIES manufacturer warranty policy was not located in the available product searches. Confirm the UPS electronics, battery and installation warranty terms with the supplier before purchase; Australian UPS distributors commonly publish separate terms for UPS equipment, batteries, commissioning and return-to-base service. ([pssdistributors.com.au](https://www.pssdistributors.com.au/ups-warranty/?utm_source=openai))

Available Now

Available through POWERSERIES and authorised Australian electrical or UPS distributors; confirm lead time, battery-cabinet configuration and commissioning requirements before ordering.


UPS Sizing Calculator




This calculator follows relevant Australian standards to ensure reliable and compliant performance. It provides an estimated recommendation based on user inputs.
Users must verify specifications before purchasing.