PowerSeries GP online double conversion UPS features 6kVA 4.8kW, 1:1 single phase, 48x120Ah battery bank and generator compatibility. Ideal for critical loads.

Alternatively Known As: PowerSeries GP Online UPS, 6 kVA Single-Phase UPS, 4.8 kW Uninterruptible Power Supply, Generator-Compatible UPS

Technical Specifications
  • UPS Topology: Online double-conversion
  • Rated Capacity: 6 kVA
  • Rated Active Power: 4.8 kW
  • Phase Configuration: 1:1 single phase
  • Battery Bank: 48 × 120 Ah batteries
  • Battery System Voltage: Confirm during site specification; GP series supports configurable high-voltage DC battery strings
  • Input Voltage Range: Approximately 110–286 VAC, subject to final model configuration
  • Output Voltage: Selectable 208/220/230/240 VAC, subject to final model configuration
  • Output Waveform: Pure sine wave
  • Transfer Time: 0 ms from mains to battery operation
  • Bypass Transfer Time: Approximately 5 ms typical
  • Generator Compatibility: Yes
  • Power Factor Correction: Input power factor up to 0.99 on the GP series
  • Protection Functions: Short circuit, overload, over-temperature, battery overcharge and over-discharge
  • Communications: RS232/USB/EPO; relay and SNMP options may be available
  • Operating Temperature: 0°C to 40°C
  • Relative Humidity: 20–95%, non-condensing
  • Noise Level: Less than approximately 58 dB at 1 metre for the tall configuration
  • Dimensions (H x L x W): 720mm x 460mm x 191mm
  • Weight: 500 kg
Key Features
  • Maintains continuous conditioned power using online double-conversion technology
  • Suitable for critical loads requiring regulated single-phase output
  • Supplied with a large-capacity 48 × 120 Ah battery bank for extended autonomy
  • Generator-compatible design for standby power integration
  • Pure sine-wave output for sensitive electronic and control equipment
  • Selectable 208 V, 220 V, 230 V or 240 V output configuration, subject to final model verification
  • Zero transfer time to battery operation under mains failure
  • LCD monitoring of input, output, load, battery and remaining runtime parameters
  • Multiple electrical protection and alarm functions
  • Suitable for data, telecommunications, industrial control and other critical-power applications
Professional Installation Requirements
  • Installation, commissioning and battery connection must be performed by suitably qualified electrical and power-system personnel. The installation should comply with AS 62040.1, AS/NZS 3000, applicable battery-installation requirements and the manufacturer’s instructions. The 48-battery bank requires appropriate isolation, overcurrent protection, ventilation, access control, earthing and battery-room risk assessment.
Applications
  • Data centres and server rooms
  • Telecommunications and network infrastructure
  • Industrial automation and process-control systems
  • Security, monitoring and communications equipment
  • Medical, laboratory and other critical electronic loads
  • Commercial facilities requiring generator-backed power continuity
Standards & Compliance
  • AS 62040.1:2019 — Uninterruptible power systems, safety requirements; applicable Australian UPS safety standard
  • AS IEC 62040.2 — Uninterruptible power systems, electromagnetic compatibility requirements
  • AS IEC 62040.3 — Uninterruptible power systems, performance and test requirements
  • AS/NZS 3000 — Electrical installations and fixed wiring requirements
  • AS/NZS 5139 — Battery-system installation requirements where the external battery bank falls within its scope
Environmental Benefits
  • Online power conditioning can reduce equipment stress and extend the service life of connected electronic loads
  • Generator compatibility supports efficient integration with standby-generation systems
  • Lead-acid batteries can be recovered and recycled through approved battery-recycling channels
  • Replaceable battery-bank architecture can extend the usable life of the UPS and reduce whole-system replacement waste
  • High-efficiency operating and ECO modes available on the GP series can reduce energy losses where compatible with the critical load
Warranty Information

No POWERSERIES-specific warranty policy was located in the available manufacturer and distributor sources. Confirm the UPS, battery-bank and commissioning warranty terms with the supplying Australian distributor before purchase; battery warranty may be separate from the UPS warranty.

Available Now

Available through POWERSERIES and authorised Australian power-protection distributors, subject to configuration, battery-bank assembly and project quotation.


UPS Sizing Calculator




This calculator follows relevant Australian standards to ensure reliable and compliant performance. It provides an estimated recommendation based on user inputs.
Users must verify specifications before purchasing.