RCD 2P 40A 30mA Type A 6kA NL1-63 Chint
Chint NL1-63 RCD features 2P 40A 30mA Type A sensitivity, 6kA and high surge immunity. Ideal for personal protection on residential and commercial circuits.
Sign in
Please login to continue to your account.
Alternatively Known As: CHINT NL1-63 RCD, 2P Type A residual current circuit breaker, 40A RCCB, safety switch
- Device Type: Residual current circuit breaker without overcurrent protection
- Poles: 2P
- Rated Current: 40A
- Rated Residual Operating Current: 30mA
- RCD Type: Type A
- Rated Short-Circuit Capacity: 6kA
- Rated Voltage: 230/240V AC
- Rated Frequency: 50/60Hz
- Insulation Voltage: 500V
- Protection Degree: IP20
- Electrical Life: 4,000 operations
- Mechanical Life: 4,000 operations
- Fault Current Indicator: Yes
- Terminal Capacity: 25/35mm² cable
- Mounting: 35mm DIN rail
- Connection: Top or bottom entry
- Dimensions (H x L x W): 86mm x 79mm x 36mm
- Weight: 0.27 kg
- Provides additional protection against electric shock and earth leakage
- Type A sensing detects sinusoidal AC and pulsating DC residual currents
- Suitable for circuits supplying modern electronic equipment
- 6kA conditional short-circuit current rating
- 30mA sensitivity for personal protection applications
- Compact two-pole modular design
- DIN rail mounting with top or bottom connection
- Built-in test function and fault current indication
- Designed for residential and commercial distribution boards
- Installation, testing and commissioning must be carried out by a licensed electrical contractor in accordance with applicable Australian wiring rules and local electrical regulations. The device provides residual-current protection only and must be coordinated with suitable overcurrent protection.
- Residential switchboards
- Commercial distribution boards
- Single-phase final circuits
- Additional personnel protection circuits
- Circuits supplying appliances and electronic equipment with pulsating DC leakage potential
- Electrical installations requiring Type A residual-current protection
- Applicable RCCB product standard: AS/NZS 61008.1:2015
- Installation and selection should comply with AS/NZS 3000:2018 and applicable amendments
- Long electrical and mechanical life can reduce replacement frequency and associated product waste
- Reusable protective device supports longer service life for electrical installations
CHINT warranty policy provides 27 months from the date of manufacture for other low-voltage apparatus supplied through authorised sales channels, subject to applicable terms and conditions.
Available through authorised CHINT distributors in Australia.