Rod Probe Level Sensor | 1300 mm Length | IO-Link Communication | High Accuracy ±5 mm | by SICK
The Rod Probe Level Sensor is designed for precise fluid level measurement, featuring a 1300 mm length and IO-Link communication for seamless integration. With a high accuracy of ±5 mm and a fast response time of 400 ms, it's perfect for continuous and switch level detection in various industrial applications, including chemical and water treatment processes.
Sign in
Please login to continue to your account.
Product Name/Title: Rod Probe Level Sensor | 1300 mm Length | IO-Link Communication | High Accuracy ±5 mm | by SICK
Brand: SICK
SKU: 1057103
Alternatively Known As: Rod Probe Level Sensor, Fluid Level Sensor with IO-Link, Continuous Level Sensor, Switch Level Sensor
- Medium: Fluids
- Measurement: Switch and Continuous
- Design: Standard amplifier
- Probe type: Rod probe
- Probe length: 1300 mm
- Process pressure: -1 bar to 10 bar
- Process temperature: -20 °C to +100 °C
- Accuracy: ±5 mm
- Reproducibility: ≤2 mm
- Resolution: <2 mm
- Response time: 400 ms
- Dielectricity constant: ≥5 for rod probe
- Conductivity: No limitation
- Maximum level change: ≤500 mm/s
- Deactivated area at process connection: 25 mm
- Deactivated area at end of probe: ≥10 mm
- MTTF: 194.3 years (EN ISO 13849-1)
- Display: Yes
- Communication interface: IO-Link
- Supply voltage: 12 V DC to 30 V DC
- Power consumption: ≤100 mA at 24 V DC without output load
- Initialization time: ≤5 s
- Protection class: III
- Connection type: Round connector M12 x 1, 5-pin
- Output signal: 1 x PNP + 1 x PNP/NPN + 4 mA to 20 mA / 0 V to 10 V
- Output load: 4 mA to 20 mA < 350 Ohm at Uv > 12 V, 0 V to 10 V > 750 Ohm at Uv ≥ 14 V
- Hysteresis: ≥2 mm
- Output current: <100 mA
- Inductive load: <1 H
- Capacitive load: 100 nF
- Enclosure rating: IP67 (EN 60529)
- Temperature drift: <0.1 mm/K
- Lower signal level: 3.8 mA to 4 mA
- Upper signal level: 20 mA to 20.5 mA
- Wetted parts: Stainless steel 1.4404 / 316L, PTFE, FKM
- Process connection: ¾" NPT
- Housing material: Plastic PBT
- Max. probe load: ≤6 Nm
- Ambient operating temperature: -20 °C to +60 °C
- Ambient storage temperature: -40 °C to +80 °C
- Dimensions (H x L x W): 30mm x 1350mm x 30mm
- Weight: 1.5 kg
- Rod probe design with 1300 mm length for versatile fluid level measurement
- Standard amplifier with switch and continuous measurement capabilities
- High accuracy sensor element with ±5 mm precision and ≤2 mm reproducibility
- Fast response time of 400 ms for real-time monitoring
- IO-Link communication interface for easy integration and diagnostics
- Robust stainless steel 1.4404 / 316L wetted parts with PTFE and FKM seals
- IP67 rated enclosure for protection against dust and water ingress
- Wide process pressure range from -1 bar to 10 bar and temperature range -20 °C to +100 °C
- Multiple output signals including PNP, NPN, 4-20 mA, and 0-10 V
- Installation should be performed by a qualified technician or electrician familiar with fluid level sensors and IO-Link communication protocols to ensure proper setup and safety compliance.
- Fluid level measurement in industrial processes
- Continuous and switch level detection in tanks and vessels
- Process monitoring in chemical, water treatment, and food industries
- AS/NZS 3000 – Wiring Rules (Electrical Installation)
- Durable stainless steel construction reduces waste and extends product life
- Energy-efficient electronics minimize power consumption during operation
- Enables precise fluid level control to reduce spillage and environmental contamination
Standard manufacturer warranty applies; please refer to SICK's official warranty policy for details.
The SICK LFP1300-B4NMB rod probe level sensor is available for immediate purchase, ideal for industrial fluid level measurement and process control applications.