Rotary Encoder ARS60 | High Resolution 720 Steps | IP66 Rated | by SICK
The Rotary Encoder ARS60 is designed for precision in industrial automation, featuring a high resolution of 720 steps per revolution and an IP66-rated robust aluminum housing. Ideal for robotics and motion control, it offers exceptional repeatability with a standard deviation of just 0.005°, ensuring reliable position feedback in safety-critical applications.
Sign in
Please login to continue to your account.
- Mean Time To Dangerous Failure (MTTFD): 300 years (EN ISO 13849-1)
- Number of steps per revolution: 720
- Measuring step deviation: 0.016°
- Error limits G: 0.046°
- Repeatability standard deviation σr: 0.005°
- Communication interface: Parallel data world
- Initialization time: 80 ms
- Code type: Binary
- Supply voltage: 10 to 32 V
- Operating current: Typically 90 mA
- Switching level of control inputs: Logic H = 0.7 x US, Logic L = 0 to 0.3 x US
- Mechanical design: Blind hollow shaft with 15 mm diameter
- Start up torque: Typically 0.6 Ncm
- Operating torque: Typically 0.4 Ncm
- Permissible movement static: ±0.3 mm radial, ±0.5 mm axial
- Permissible movement dynamic: ±0.1 mm radial, ±0.2 mm axial
- Operating speed: Up to 3,000 min⁻¹
- Bearing lifetime: 3.6 x 10^9 revolutions
- EMC compliance: EN 61000-6-2 and EN 61000-6-3
- Enclosure rating: IP66 (IEC 60529)
- Operating temperature range: -20°C to +85°C
- Storage temperature range: -40°C to +100°C
- Shock resistance: 50 g, 11 ms
- Vibration resistance: 20 g, 10 Hz to 2,000 Hz
- Dimensions (H x L x W): 60mm x 60mm x 60mm
- Weight: 0.3 kg
- High resolution with 720 steps per revolution
- Robust aluminum die cast housing with IP66 rating
- Blind hollow shaft with 15 mm diameter and front clamp
- Low start-up torque of typically 0.6 Ncm
- High repeatability with standard deviation of 0.005°
- Wide operating temperature range from -20°C to +85°C
- Resistance to shocks up to 50 g and vibrations up to 20 g
- Cable connection with 22 wires, 5 m length
- Complies with multiple international certifications including EU, UK, ACMA, cULus, and China-RoHS
- Installation should be performed by qualified personnel familiar with electrical and safety standards to ensure proper integration and compliance.
- Industrial automation and control systems
- Robotics and motion control
- Precision measurement in manufacturing processes
- Safety-related applications requiring reliable position feedback
- AS/NZS 3000 – Wiring Rules (Electrical Installation)
- AS/NZS 3112 – Plugs and Socket-Outlets (Type I Plug)
- Durable design reduces need for frequent replacements, minimizing waste
- Energy-efficient operation with low operating current of typically 90 mA
Standard manufacturer warranty applies; please refer to SICK's official warranty policy.
The SICK ARS60-HAM00720 rotary encoder is available for immediate purchase, ideal for industrial automation and safety-critical applications.