Safety Controller UE410-MM3 | SIL 3 & Category 4 | 20-Year Mission Time | by SICK
The UE410-MM3 Safety Controller is designed for industrial safety control systems, featuring a SIL 3 safety integrity level and Category 4 compliance. With a long mission time of 20 years and low power consumption, it’s perfect for machine safety monitoring and automation applications, ensuring reliable performance and compliance with safety standards.
Sign in
Please login to continue to your account.
Product Name/Title: Safety Controller UE410-MM3 | SIL 3 & Category 4 | 20-Year Mission Time | by SICK
Brand: SICK
SKU: 6034482
Alternatively Known As: Safety controller module, UE410 safety controller, SICK safety relay, industrial safety controller
- Safety integrity level: SIL 3 (IEC 61508)
- Category: Category 4 (EN ISO 13849)
- Performance level: PL e (EN ISO 13849)
- PFHD: 2.5 x 10^-9 (EN ISO 13849)
- Mission time: 20 years (EN ISO 13849)
- Inputs: 2 safety inputs, 2 switching inputs, 4 muting inputs
- Outputs: 2 safety outputs, 2 test outputs, 2 application diagnostic outputs
- Connection type: Plug-in screw-type terminals
- Protection class: III (EN 61140)
- Supply voltage: 24 V DC (19.2 V DC to 30 V DC)
- Residual ripple: ≤ 10%
- Power consumption: ≤ 3 W (DC)
- Switch-on time: ≤ 10 s
- Enclosure rating: Housing IP40, Terminals IP20 (EN 60529)
- Operating temperature: -25 °C to +55 °C
- Storage temperature: -25 °C to +70 °C
- Humidity: ≤ 95%, non-condensing
- EMC: Class A (EN 61000-6-2, EN 55011)
- Vibration resistance: 5 g RMS, 5 Hz to 500 Hz (EN 60068-2-64)
- Dimensions (H x L x W): 96.5mm x 120.8mm x 22.5mm
- Weight: 0.18 kg
- Main module with rotary switch configuration
- Manual or automatic restart interlock configurable
- External device monitoring (EDM)
- Differentiation between man and material (muting)
- Override and concurrence monitoring
- Monitoring of total muting time and sensor gap
- End of muting by ESPE
- LED display elements for status indication
- Installation should be performed by qualified personnel familiar with safety control systems and electrical standards to ensure compliance and safety.
- Industrial safety control systems
- Machine safety monitoring
- Automation safety applications
- AS/NZS 4801 – Occupational Health & Safety Management Systems
- Low power consumption of ≤ 3 W reduces energy usage
- Long mission time of 20 years supports sustainable operation
- Complies with RoHS and other environmental regulations
Standard manufacturer warranty applies; please refer to SICK for specific warranty terms.
The SICK UE410-MM3 Safety Controller is available for immediate purchase, ideal for industrial safety and automation applications.