Safety Sensor Evaluation Unit RLY3-OSSD300 | SIL 3 & Category 4 | 24V DC Supply | by RELY
The RLY3-OSSD300 Safety Sensor Evaluation Unit is designed for evaluating safety sensors with OSSDs, featuring a SIL 3 safety integrity level and Category 4 compliance. With a low power consumption of ≤ 2.5 W and a response time of just 12 ms, it's perfect for industrial safety monitoring and control applications, ensuring reliable operation in demanding environments.
Sign in
Please login to continue to your account.
Alternatively Known As: Safety Sensor Evaluation Unit, OSS Detection Relay, Safety Relay Module, SICK Safety Controller
- Safety integrity level: SIL 3 (IEC 61508)
- Category: Category 4 (ISO 13849-1)
- Performance level: PL e (ISO 13849-1)
- Mean probability of dangerous failure per hour (PFHD): 1.0 x 10^-9
- Mission time: 20 years (ISO 13849-1)
- Stop category: 0 (IEC 60204-1)
- Inputs: 2 safety inputs, 1 input for reset pushbutton or EDM
- Outputs: 3 enabling current paths (safe), 2 application diagnostic outputs (not safe), 1 test pulse output (not safe)
- Voltage supply: PELV or SELV, 24 V DC (16.8 V to 30 V)
- Power consumption: ≤ 2.5 W
- Response time (enabling current paths): 12 ms
- Contact material: Silver alloy, gold flashed
- Switching voltage: 10 V AC to 230 V AC / 10 V DC to 230 V DC
- Switching current: 10 mA to 6 A
- Mechanical life: 10 million switching cycles
- Enclosure rating: IP20
- Operating temperature: -25 °C to +55 °C
- Storage temperature: -25 °C to +70 °C
- Air humidity: ≤ 95%, non-condensing
- Dimensions (H x L x W): 124.6mm x 85.5mm x 18mm
- Weight: 0.15 kg
- Compatible with safety sensors with OSSDs
- Safety integrity level SIL 3 (IEC 61508)
- Category 4 (ISO 13849-1) safety category
- Performance level PL e (ISO 13849-1)
- Sequence monitoring sensor monitoring
- Automatic and manual reset options
- External device monitoring (EDM) supported
- Front connector with spring terminals
- LED display elements for status indication
- Hard wired configuration method
- 24 V DC supply voltage with low power consumption (≤ 2.5 W)
- 3 enabling current paths (safe) and multiple diagnostic outputs
- Response time for enabling current paths: 12 ms
- IP20 enclosure rating
- Operating temperature range: -25 °C to +55 °C
- Installation should be performed by a qualified professional familiar with safety sensor systems and electrical standards to ensure compliance and safety.
- Evaluation unit for safety sensors with OSSDs
- AS/NZS 4801 – Occupational Health & Safety Management Systems
- Low power consumption reduces energy usage
- Long mission time of 20 years supports sustainability
- Complies with RoHS for hazardous substance reduction
Warranty details available upon request from the manufacturer.
The SICK RLY3-OSSD300 Safety Sensor Evaluation Unit is available for immediate purchase, ideal for industrial safety monitoring and control applications.