Transducer Hydrostatic Sewage 0-4m Ceramic 24m Lead 4-20mA Matelec
Matelec hydrostatic transducer features 0-4m sewage range, ceramic diaphragm and 4-20mA output on 24m lead. Ideal for tank level sensing.
Sign in
Please login to continue to your account.
Alternatively Known As: Submersible Hydrostatic Level Sensor, Sewage Level Transmitter, Wastewater Level Transducer, 4–20 mA Tank Level Sensor
- Model: FPC-12575-24-SE
- Measurement Range: 0–4 m water depth
- Output Signal: 4–20 mA DC
- Supply Voltage: 12–30 V DC, loop powered
- Accuracy: ±0.5% full scale
- Overload Pressure: 1.5 times full scale
- Response Time: 10 ms
- Diaphragm: Ceramic
- Housing Material: 316L stainless steel
- Protection Rating: IP68
- Electrical Connection: 3 wires with breather tube
- Cable Length: 24 m
- Cable Diameter: 7.5 mm OD
- Cable Material: PUR polyurethane
- Operating Temperature: −10°C to 70°C
- Operating Life: More than 1 × 10⁸ pressure cycles
- Dimensions (H x L x W): 160mm x 99mm x 99mm
- Weight: 1.5 kg
- Continuous hydrostatic level measurement for sewage and wastewater
- 0–4 m calibrated depth range with 4–20 mA analogue output
- Robust ceramic diaphragm for contaminated-water applications
- 316L stainless steel construction
- IP68-rated sensor for submerged installation
- 24 m PUR cable with integral breather tube for gauge-pressure compensation
- Suitable for tank, wet-well and wastewater level monitoring
- Excellent repeatability and long-term stability
- Installation and electrical connection should be completed by a suitably qualified electrical or instrumentation technician. Install the sensor clear of turbulence and obstructions, maintain the breather tube without kinks or blockages, and connect to a compatible 12–30 V DC loop-powered input in accordance with the manufacturer’s instructions.
- Sewage wet-well level monitoring
- Wastewater treatment tanks
- Trade-waste tanks
- Stormwater and rainwater tanks
- Pump station level control
- Raw-water and contaminated-water storage vessels
- 316L stainless steel components can be recovered through established metal-recycling streams at end of service life
- Long operating life can reduce replacement frequency and associated material waste
- Continuous level feedback can support efficient pump control and help reduce overflow events
- Designed for wastewater and sewage monitoring without requiring refrigerants or other high-impact consumables
MATElec Australia provides a minimum 12-month warranty against defects in materials and workmanship from the date of dispatch, subject to its warranty conditions, correct installation and use in Australia. ([matelecaustralia.com.au](https://www.matelecaustralia.com.au/hubfs/Electrical-Product-Warranty-Statement.pdf))
Available through MATElec Australia and authorised Australian distributors; confirm current stock and lead time with the distributor.