- Measurement principle: Ultrasonic sensor
- Medium: Fluids
- Nominal width measuring tube: DN 15
- Process temperature: 0 °C to +80 °C
- Process pressure: ≤ 16 bar
- Minimum flow: ≥ 0.9 l/min
- Maximum flow: ≤ 36 l/min
- Inlet zone: 30 cm
- Output zone: 5 cm
- Conductivity: No limitation
- Measurement accuracy: ± 2% of measured value + 0.15% of measuring range limit
- Repeatability: ≤ 0.5%
- Resolution: 0.006 l/min
- Response time: 100 ms to 4.2 s
- Supply voltage: 18 V DC to 30 V DC
- Power consumption: ≤ 180 mA
- Switch-on time: ≤ 5 s
- Connection type: Round connector M12 x 1, 5-pin
- Output signal: Analog output 4 mA to 20 mA, pulse/status output PNP/NPN transistor
- Output current: < 100 mA
- Output load: < 500 Ohm
- Enclosure rating: IP67
- Process connection: Clamp (DIN 11864-3)
- Wetted parts: PPSU EPDM
- Housing material: PPSU
- Weight: 350 g
- Dimensions (H x L x W): 100mm x 120mm x 50mm
- Weight: 0.35 kg
- Ultrasonic sensor measurement principle for accurate flow detection
- Suitable for fluids with nominal width measuring tube DN 15
- Process temperature range from 0 °C to +80 °C
- Process pressure up to 16 bar
- High measurement accuracy of ± 2% of measured value plus 0.15% of measuring range limit
- Repeatability of ≤ 0.5%
- Fast response time options from 100 ms to 4.2 s
- Analog output signals with 4 mA to 20 mA current flow
- IP67 rated enclosure for robust protection
- Clamp process connection (DIN 11864-3) with PPSU and EPDM wetted parts
- Installation should be performed by qualified personnel familiar with ultrasonic flow sensors and electrical connections to ensure accurate measurement and safety.
- Measurement of fluid flow in industrial processes
- Monitoring flow rates in water treatment and chemical industries
- Flow monitoring in food and beverage production
- Use in pharmaceutical and biotechnology fluid systems
- AS/NZS 3000 – Wiring Rules (Electrical Installation)
- Non-invasive ultrasonic measurement reduces contamination risk and fluid waste
- Durable materials and IP67 protection extend product life and reduce replacement frequency
Standard manufacturer warranty applies; please refer to SICK's official warranty policy for details.
The SICK FFUS15-1C1IO Ultrasonic Flow Sensor DN 15 is available for immediate purchase, ideal for industrial fluid flow measurement applications.