UPS 60kVA Excluding Batteries e-PowerSeries
e-PowerSeries 60kVA UPS features high-capacity power protection, supplied without batteries for external battery banks. Ideal for data centres and critical loads.
Sign in
Please login to continue to your account.
Alternatively Known As: 60 kVA Three-Phase UPS, Online UPS, External Battery UPS, e-PowerSeries Uninterruptible Power Supply
- Rated Capacity: 60 kVA
- Topology: Online UPS with double-conversion architecture
- Input: Three-phase, four-wire AC
- Output: Three-phase, four-wire AC
- Nominal Output Voltage: 400 V AC
- Output Frequency: 50 Hz ±0.1%
- Output Power Factor: 0.8 lagging
- Input Voltage Range: 310–480 V AC
- Input Frequency Range: 45–55 Hz
- Output Waveform: Pure sine wave
- Output Voltage Distortion: ≤3% on linear load
- Overload Capacity: 105% continuous; up to 300% for 60 seconds
- Battery Configuration: External battery bank; batteries excluded
- DC Battery Voltage Range: 120–360 V DC
- Battery Charging Current: 1–10 A
- Efficiency: ≥95%
- Bypass: Maintenance bypass available
- Cooling: Forced-air cooling
- Operating Temperature: -10°C to 50°C
- Operating Humidity: 30–90% relative humidity, non-condensing
- Dimensions (H x L x W): 1400mm x 850mm x 600mm
- Weight: 430 kg
- 60 kVA capacity for high-demand critical loads
- Designed for three-phase input and three-phase output systems
- Supplied without batteries for connection to a separately specified external battery bank
- Pure sine-wave output for sensitive electronic and IT equipment
- Maintenance bypass for service and operational continuity
- LCD and LED status indication
- Protection against overload, short circuit, DC overvoltage and undervoltage
- Generator-compatible operation
- Intelligent battery management capability
- Suitable for data centres, communications infrastructure and other critical loads
- Installation, battery-bank connection, commissioning and servicing must be performed by a suitably licensed electrical contractor and qualified UPS technician. Installation should comply with AS/NZS 3000 and the manufacturer's requirements, including battery isolation, earthing, ventilation, cable sizing and fault protection.
- Data centres and server rooms
- Telecommunications and network infrastructure
- Industrial control systems
- Medical and other critical facilities
- Commercial buildings requiring conditioned backup power
- Critical process and automation loads
- AS 62040.1 / AS/NZS 62040.1: Applicable UPS safety requirements; confirm model-specific certification with the supplier
- AS IEC 62040.3: Applicable UPS performance and testing standard; confirm model-specific declaration with the supplier
- AS/NZS 3000: Electrical installation and wiring requirements for permanent UPS installation
- AS/NZS 60335.2.29: Consider for battery-charging functions where applicable to the external battery-bank configuration
- High operating efficiency of at least 95% can reduce energy losses during continuous operation
- External battery-bank configuration allows batteries to be replaced independently of the UPS cabinet, potentially extending equipment service life
- Supports energy-efficient critical-power infrastructure and reduced downtime-related equipment waste
- Electronic components and metal cabinet materials should be recovered through appropriate electrical and e-waste recycling channels at end of life
A manufacturer warranty policy specific to the e-PowerSeries 60 kVA UPS was not located. Confirm warranty duration, parts coverage, labour coverage and battery exclusions with the authorised supplier before purchase.
Available through the brand or authorised electrical and critical-power distributors, subject to configuration, external battery-bank requirements and project quotation.
UPS Sizing Calculator
This calculator follows relevant Australian standards to ensure reliable and compliant performance. It provides an estimated recommendation based on user inputs.
Users must verify specifications before purchasing.