Bulk Solids Level Sensor Continuous Measurement W-band Frequency Variant-19 SICK
The Bulk Solids Level Sensor is designed for continuous measurement of bulk solids, utilizing W-band frequency technology for precise readings.
Sign in
Please login to continue to your account.
- Medium: Bulk solids
- Measurement: Continuous
- Probe type: Thread with integrated horn antenna made from PEEK
- Frequency band: W-band (75 to 85 GHz)
- Measuring range: Up to 120 m, recommended up to 20 m for thread version
- Angle of dispersion: 7°
- Process pressure: -1 bar to 20 bar (-100 kPa to 2000 kPa)
- Process temperature: -40 °C to +200 °C
- ATEX approval: IEC Ex db IIC T6...T1, Ga/Gb, Gb
- Type examination: IECEx KIWA 20.0014X
- RoHS certificate: Yes
- HART communication: Yes
- Display: Installed with pushbutton operation
- Accuracy: ≤ 5 mm
- Non-repeatability: ≤ 1 mm
- Digital measurement resolution: < 1 mm
- Analog measurement resolution: 0.3 µA
- Measurement cycle time: Approx. 700 ms
- Step response time: ≤ 3 s
- MTBF: 3.37 million hours
- Supply voltage: 9 V DC to 30 V DC
- Protection class: I (IEC 61010-1)
- Connection type: ½" NPT / cable gland PA (5 mm - 9 mm)
- Output signal: 4 mA to 20 mA / HART
- Contamination rating: 4
- Enclosure rating: IP67
- EMC: EN 61326-1
- Start-up current: < 3.6 mA
- Overvoltage category: III (IEC 61010-1)
- Short-circuit protection: Yes
- Isolation: Yes
- Process connection: Thread 1 ½'' NPT PN20, ASME B1.20.1 / 316L
- Housing material: Aluminum die cast AlSi10Mg, powder-coated
- Sealing material: FKM (SHS FPM 70C3 GLT)
- Antenna material: PEEK
- Ambient operating temperature: -40 °C to +80 °C
- Storage temperature: -40 °C to +80 °C
- Dimensions (H x L x W): 150mm x 60mm x 60mm
- Weight: 2.5 kg
- Continuous measurement of bulk solids using W-band frequency (75-85 GHz)
- Probe type: Thread with integrated horn antenna made from PEEK
- Measuring range up to 120 m, recommended up to 20 m for thread version
- Process pressure range from -1 bar to 20 bar
- Process temperature range from -40 °C to +200 °C
- ATEX approved for hazardous areas (IEC Ex db IIC T6...T1, Ga/Gb, Gb)
- HART communication interface with installed display and pushbutton control
- High accuracy sensor element with ≤ 5 mm accuracy and ≤ 1 mm non-repeatability
- Robust aluminum die cast housing with powder coating and IP67 protection
- Short-circuit protection and isolation for electrical safety
- Installation must be performed by qualified personnel familiar with hazardous area equipment and electrical safety standards.
- Continuous measurement of bulk solids in industrial processes
- Suitable for use in harsh environments with process pressures up to 20 bar
- Ideal for applications requiring high accuracy level measurement in bulk solids
- AS/NZS 60035 – Electrical Equipment in Explosive Atmospheres
- Enables precise measurement to optimize material usage and reduce waste
- Robust design reduces need for frequent replacements, minimizing waste
- Complies with RoHS directive ensuring reduced hazardous substances
Standard manufacturer warranty applies. Please refer to SICK for detailed warranty terms.
The SICK LBR-ICTTDBJHKAX sensor is available for immediate purchase, ideal for industrial bulk solids measurement applications.