FLEXI LOOP Safety Device SIL 3 & Category 4 Dual-Channel OSSD Outputs SICK
The FLEXI LOOP Safety Device is engineered for industrial safety monitoring and control, featuring a SIL 3 safety integrity level and Category 4 compliance.
Sign in
Please login to continue to your account.
Alternatively Known As: Flexi Loop Safety Device, FLN OSSD 1100108, SICK Safety Loop Module
- Safety integrity level: SIL 3 (IEC 61508)
- Category: Category 4 (EN ISO 13849)
- Performance level: PL e (EN ISO 13849)
- Mean probability of dangerous failure per hour (PFHD): 0.76 x 10^-9
- Mission time: 20 years
- Connection types: Female M12 8-pin for safety device, Male M12 5-pin for Flexi Loop input, Female M12 5-pin for Flexi Loop output
- Number of non-safe inputs: 1
- Number of non-safe outputs: 1
- Power supply output for external devices: 24 V DC, ≤ 2 A
- Operating voltage: 24 V DC (16.8 V DC to 30 V DC)
- Power consumption: 45 mA
- Input voltage for OSSD inputs: HIGH 13 V DC to 30 V DC, LOW -5 V DC to 5 V DC
- Output type: Highside driver, short-circuit protected
- Output current: ≤ 500 mA
- Protection class: III (EN 61140)
- Enclosure rating: IP65 and IP67 (EN 60529)
- Operating temperature range: -25 °C to +55 °C
- Storage temperature range: -25 °C to +70 °C
- Dimensions (H x L x W): 48mm x 18mm x 68mm
- Weight: 0.1 kg
- Safety integrity level SIL 3 (IEC 61508)
- Category 4 (EN ISO 13849) and Performance level PL e (EN ISO 13849)
- Diagnostic and monitoring functions including cross-circuit, short-circuit, discrepancy and sequence error monitoring
- Dual-channel OSSD outputs for safety sensor connection
- Power supply output for external devices
- Robust IP65 and IP67 enclosure rating for harsh environments
- Wide ambient operating temperature range from -25 °C to +55 °C
- Installation should be performed by qualified personnel familiar with safety systems and electrical standards to ensure compliance and optimal performance.
- Industrial safety monitoring and control
- Machine safety systems requiring dual-channel OSSD outputs
- Integration with Flexi Soft safety controllers
- AS/NZS 4801 – Occupational Health & Safety Management Systems
- Enhances machine safety reducing risk of accidents and associated environmental hazards
- Durable IP65/IP67 rated enclosure reduces need for frequent replacements
Standard manufacturer warranty applies; please refer to SICK for specific warranty terms.
The SICK FLN-OSSD1100108 FLEXI LOOP safety device is available for immediate purchase, ideal for industrial safety and machine control applications.