Fluid Level Sensor IO-Link & Cable Probe 2000 mm Length SICK
The Fluid Level Sensor with IO-Link and cable probe is designed for precise fluid level measurement in industrial processes.
Sign in
Please login to continue to your account.
- Medium: Fluids
- Measurement: Switch, Continuous
- Design: Standard amplifier
- Probe type: Cable probe
- Probe length: 2000 mm
- Process pressure: -1 bar to 10 bar
- Process temperature: -20 °C to +100 °C
- Accuracy of sensor element: ±5 mm
- Reproducibility: ≤2 mm
- Resolution: <2 mm
- Response time: 400 ms
- Dielectricity constant: ≥5 for rod probe / cable probe ≥1.8 with coaxial tube
- Conductivity: No limitation
- Maximum level change: ≤500 mm/s
- Deactivated area at process connection: 25 mm
- Deactivated area at end of probe: ≥10 mm
- MTTF: 194.3 years (EN ISO 13849-1)
- Display: Yes
- Communication interface: IO-Link
- Supply voltage: 12 V DC to 30 V DC
- Power consumption: ≤100 mA at 24 V DC without output load
- Initialization time: ≤5 s
- Protection class: III
- Connection type: Round connector M12 x 1, 5-pin
- Output signal: 1 x PNP + 1 x PNP/NPN + 4 mA to 20 mA / 0 V to 10 V
- Output load: 4 mA to 20 mA < 350 Ohm at Uv > 12 V, 0 V to 10 V > 750 Ohm at Uv ≥ 14 V
- Hysteresis: ≥2 mm
- Output current: <100 mA
- Inductive load: <1 H
- Capacitive load: 100 nF
- Enclosure rating: IP67 (EN 60529)
- Temperature drift: <0.1 mm/K
- Lower signal level: 3.8 mA to 4 mA
- Upper signal level: 20 mA to 20.5 mA
- Wetted parts: Stainless steel 1.4404 / 316L PTFE FKM
- Process connection: G ¾ A
- Housing material: Plastic PBT
- Max. probe load: ≤6 Nm
- Ambient operating temperature: -20 °C to +60 °C
- Ambient temperature, storage: -40 °C to +80 °C
- Dimensions (H x L x W): 30mm x 2000mm x 30mm
- Weight: 0.5 kg
- Suitable for fluids with process pressure from -1 bar to 10 bar
- Measurement types: switch and continuous
- Standard amplifier design with cable probe
- Probe length of 2000 mm
- High accuracy with ±5 mm sensor element accuracy
- Fast response time of 400 ms
- Communication via IO-Link interface
- Protection class IP67 for harsh environments
- Stainless steel wetted parts for corrosion resistance
- Multiple output signals including PNP, NPN, 4-20 mA, and 0-10 V
- Installation should be performed by qualified personnel familiar with fluid level sensor setup and IO-Link communication protocols to ensure proper operation and safety.
- Fluid level measurement in industrial processes
- Continuous and switch level detection in liquids
- Use in chemical, pharmaceutical, and food industries
- AS/NZS 4801 – Occupational Health & Safety Management Systems
- Enables precise fluid level monitoring to reduce waste and prevent spills
- Durable stainless steel construction extends product life and reduces replacement frequency
Standard manufacturer warranty applies. Please refer to SICK's official warranty policy for details.
The SICK LFP2000-E4NMB fluid level sensor is available for immediate purchase, ideal for industrial fluid level monitoring applications.