MCB 1P 40A 6kA C Curve DIN Rail NB1-63 Chint
Chint NB1-63 1P 40A MCB features 6kA breaking capacity, C-curve thermal-magnetic protection and DIN rail mount to IEC 60898. For domestic and commercial boards.
Sign in
Please login to continue to your account.
Alternatively Known As: CHINT NB1-63 MCB, 40A DIN Rail Circuit Breaker, Single-Pole Thermal-Magnetic Circuit Breaker
- Rated Current: 40 A
- Number of Poles: 1P
- Rated Voltage: 230 V AC
- Rated Frequency: 50/60 Hz
- Breaking Capacity: 6 kA
- Tripping Characteristic: C curve, 5–10 times rated current
- Insulation Voltage: 500 V
- Impulse Withstand Voltage: 4 kV
- Connection: Top or bottom feed
- Terminal Capacity: 1–25 mm² cable
- Terminal Tightening Torque: 2.0 N·m
- Mounting: TH35-7.5 DIN rail
- Protection Degree: IP20
- Mechanical Life: 20,000 operations
- Electrical Life: 4,000 operations
- Energy Limiting Class: 3
- Dimensions (H x L x W): 82mm x 75.5mm x 18mm
- Weight: 0.12 kg
- Thermal-magnetic protection against overload and short-circuit currents
- C-curve operation suited to mixed loads and circuits with moderate inrush current
- 6 kA rated short-circuit breaking capacity
- Single-pole configuration for compact distribution-board installation
- DIN rail mounting with top or bottom cable connection
- Can be used for circuit isolation and infrequent switching
- Compatible with selected CHINT auxiliary, alarm, shunt-release and undervoltage accessories
- Installation and connection to mains wiring must be performed by a licensed electrician in accordance with AS/NZS 3000 and the product installation instructions. Confirm fault levels, discrimination and suitability for the specific installation before selection.
- Domestic switchboards and distribution boards
- Commercial electrical distribution boards
- Lighting and general power circuits
- Control panels and low-voltage AC installations
- Overload and short-circuit protection for mixed-load circuits
- IEC/EN 60898-1 product standard
- AS/NZS 60898.1:2024 is the applicable Australian/New Zealand standard for household and similar AC miniature circuit breakers; verify approval and RCM requirements for the exact Australian SKU
- Installation must comply with AS/NZS 3000
- Metallic components such as copper and steel can be recovered through appropriate electrical-equipment recycling streams
- Reusable reset operation reduces replacement waste after transient overloads or short-circuit events
- Long mechanical and electrical life can reduce replacement frequency over the product service life
CHINT general warranty policy provides 27 months from the date of manufacture for other low-voltage apparatus, subject to authorised sales channels, contract terms and applicable warranty conditions.
Available through authorised CHINT distributors in Australia.