MCB 2P 10A 10kA D Curve DIN Rail NB1-63H Chint
Chint NB1-63H 2P 10A MCB features 10kA breaking capacity, D-curve thermal-magnetic protection and DIN rail mount to IEC 60898. For domestic and commercial boards.
Sign in
Please login to continue to your account.
Alternatively Known As: 2P MCB, Double-Pole Circuit Breaker, DIN Rail MCB, Thermal-Magnetic Circuit Breaker
- Rated Current: 10 A
- Number of Poles: 2P
- Tripping Characteristic: D curve, 10–14 times rated current
- Rated Voltage: 230/400–240/415 V AC
- Rated Frequency: 50/60 Hz
- Breaking Capacity: 10 kA
- Energy Limiting Class: 3
- Rated Impulse Withstand Voltage: 4 kV
- Protection Degree: IP20
- Electrical Life: 10,000 operations
- Mechanical Life: 20,000 operations
- Terminal Connection: Cable, U-type busbar or pin-type busbar
- Maximum Cable Terminal Size: 25 mm²
- Mounting: 35 mm DIN rail according to EN 60715
- Connection: Top or bottom feed
- Dimensions (H x L x W): 86mm x 78mm x 36mm
- Weight: 0.22 kg
- Two-pole protection and isolation for single-phase circuits
- D-curve thermal-magnetic protection for loads with high starting or inrush currents
- 10 kA short-circuit breaking capacity
- Compact modular design occupying 36 mm of DIN rail width
- DIN rail fast-clip mounting
- Suitable for domestic, commercial and light industrial distribution boards
- Visible contact-position indication
- Compatible with selected CHINT auxiliary, shunt-trip, undervoltage and alarm accessories
- Installation, testing and commissioning must be performed by a licensed electrician in accordance with AS/NZS 3000, the switchboard manufacturer’s requirements and applicable local regulations. Confirm fault level, conductor sizing, discrimination and required Australian approvals before use.
- Domestic distribution boards
- Commercial switchboards
- Control panels and sub-distribution boards
- Circuits supplying transformers, motors, lamps and other loads with high inrush current
- Overload and short-circuit protection for AC final and sub-circuits
- Designed and tested to IEC/EN 60898-1; AS/NZS 60898.1:2024 is the applicable Australian/New Zealand standard for AC circuit-breakers of this type. Verify RCM marking and local approval requirements before Australian installation.
- Installation must comply with AS/NZS 3000 Wiring Rules.
- Thermoplastic housing and metal components can be separated for recycling at end of service life
- RoHS declaration is available for the NB1-63/NB1-63H product family
- Long mechanical life can reduce replacement frequency and associated material waste
- DIN rail mounting allows replacement of the breaker without replacing the complete switchboard assembly
27-month CHINT manufacturer warranty from the date of manufacture for other low-voltage apparatus, subject to authorised sales channels, correct storage, installation, operation and maintenance. Local distributor terms may also apply.
Available through authorised CHINT distributors in Australia.