Chint NB1-63 2P 25A MCB features 6kA breaking capacity, D-curve thermal-magnetic protection and DIN rail mount to IEC 60898. For domestic and commercial boards.
Sign in
Please login to continue to your account.
Alternatively Known As: CHINT NB1-63 D25 2P MCB, 2-Pole DIN Rail Circuit Breaker, Thermal-Magnetic Circuit Breaker
- Product Series: NB1-63
- Rated Current: 25 A
- Number of Poles: 2P
- Rated Voltage: 400 V AC
- Rated Frequency: 50/60 Hz
- Breaking Capacity: 6 kA
- Tripping Characteristic: D curve, 10–14 × In instantaneous magnetic release
- Insulation Voltage: 500 V
- Impulse Withstand Voltage: 4 kV
- Terminal Capacity: 1–25 mm² cable
- Terminal Tightening Torque: 2.0 N·m
- Mounting: 35 mm TH35 DIN rail
- Connection: Top or bottom feed; cable, U-type busbar or pin-type busbar
- Protection Degree: IP20
- Energy Limiting Class: 3
- Mechanical Life: 20,000 operations
- Electrical Life: 4,000 operations
- Operating Temperature: -5 °C to +40 °C
- Dimensions (H x L x W): 82mm x 75.5mm x 36mm
- Weight: 0.22 kg
- Thermal-magnetic overload and short-circuit protection
- D-curve operation for circuits with high inrush currents, including transformers and motors
- 6 kA short-circuit breaking capacity
- Two-pole switching for compact distribution-board protection
- Compact two-module DIN rail format
- Dual terminal arrangement for cable and busbar connections
- Compatible with selected NB1-63 auxiliary, alarm, shunt-trip and undervoltage accessories
- Suitable for residential, commercial and light industrial distribution boards
- Installation, selection and testing must be performed by a licensed electrical contractor in accordance with AS/NZS 3000 and applicable local regulatory requirements. Confirm the D-curve characteristic, fault level, discrimination and enclosure suitability before installation.
- Residential distribution boards
- Commercial switchboards
- Light industrial control and distribution panels
- Protection of transformer and motor circuits with high starting currents
- Overload and short-circuit protection for low-voltage AC circuits
- AS/NZS 60898.1 is the applicable Australian/New Zealand product standard for miniature circuit breakers of this type; verify the specific product approval and RCM requirements before use.
- AS/NZS 3000 applies to selection, installation and testing within Australian electrical installations.
- Manufacturer documentation specifies IEC/EN 60898-1; Australian acceptance should be confirmed for the intended installation and jurisdiction.
- Long mechanical and electrical service life can reduce replacement frequency and associated material waste.
- Metal and engineering-polymer components may be recoverable through appropriate electrical equipment recycling streams.
- DIN rail construction supports straightforward replacement and maintenance without replacing the complete distribution assembly.
CHINT warranty policy states 27 months from the date of manufacture for other low-voltage apparatus sold through authorised sales channels, subject to the applicable policy terms and exclusions.
Available through authorised CHINT distributors in Australia.