Chint NB1-63H 2P 63A MCB features 10kA breaking capacity, B-curve thermal-magnetic protection and DIN rail mount to IEC 60898. For domestic and commercial boards.
Sign in
Please login to continue to your account.
Alternatively Known As: 2P 63A MCB, 63A B-Curve Circuit Breaker, DIN-Rail Miniature Circuit Breaker, NB1-63H/B63 2P
- Rated Current: 63 A
- Number of Poles: 2P
- Tripping Characteristic: B curve, 3–5 × In
- Rated Voltage: 230/400–240/415 V AC
- Rated Frequency: 50/60 Hz
- Breaking Capacity: 10 kA
- Energy Limiting Class: 3
- Rated Impulse Withstand Voltage: 6 kV
- Dielectric Test Voltage: 2 kV for 1 minute
- Terminal Capacity: Up to 25 mm² cable
- Tightening Torque: 2.5 N·m
- Mounting: 35 mm EN 60715 DIN rail
- Protection Degree: IP20
- Mechanical Life: 20,000 operations
- Electrical Life: 10,000 operations
- Maximum Power Loss: 5 W per pole
- Operating Temperature: -25 °C to +70 °C
- Accessories: Auxiliary contact, shunt release, undervoltage release and alarm contact compatible
- Dimensions (H x L x W): 86mm x 78mm x 36mm
- Weight: 0.22 kg
- Thermal-magnetic protection against overload and short-circuit currents
- B-curve operation suited to residential, commercial and long-cable circuits
- 10 kA rated short-circuit breaking capacity
- Two-pole switching and isolation
- Compact 2-module DIN-rail format
- Top or bottom connection suitable for cable and busbar wiring
- Visual contact position indication
- Compatible with selected CHINT modular accessories
- Installation, selection and testing must be performed by a licensed electrician in accordance with AS/NZS 3000 and applicable local electrical regulations. Confirm that the prospective fault current at the installation point does not exceed the breaker's 10 kA capacity.
- Residential switchboards and consumer units
- Commercial electrical distribution boards
- Industrial control and distribution panels
- Overload and short-circuit protection for lighting and general-purpose circuits
- Isolation and protection of two-pole AC circuits
- AS/NZS 60898.1: applicable Australian/New Zealand product standard for circuit-breakers for household and similar AC installations; verify model-specific approval and RCM requirements before installation
- AS/NZS 3000: installation and wiring selection requirements for Australian electrical installations
- CHINT NB1-63H product documentation lists IEC/EN 60898-1 compliance and an SAA certificate for the product family
- Thermal-magnetic protection can help limit equipment damage and reduce premature replacement waste
- Long mechanical and electrical operating life supports extended service intervals
- Modular construction allows the breaker to be replaced independently rather than replacing the complete switchboard assembly
- Metal and thermoplastic components can be separated for appropriate end-of-life recycling where local facilities accept electrical equipment
CHINT warranty policy provides 27 months from the date of manufacture for other low-voltage apparatus sold through authorised sales channels, subject to applicable contract and local warranty terms.